{"title":"Double probe based in piezoelectric sensors for local pulse wave velocity assessment","authors":"T. M. Lopes, C. Correia","doi":"10.1109/ENBENG.2012.6331386","DOIUrl":null,"url":null,"abstract":"Local pulse-wave velocity (PWV) is recognized as the simplest and most reproducible process of non-invasively assessing the vascular marker of arterial stiffness that allowing the risk of cardiovascular diseases to be determinate. Devices currently available for local PWV measurement have not yet been generalized to clinical practice since they require high technical expertise and most of them are limited in precision, due to the lack of reliable signal processing methods. This work describes a new type of probes, based on a piezoelectric sensor in different configurations, single probe and double probe. The principle of PWV measurement involves determination of the pulse transit time between the signals acquired simultaneously by both piezoelectric placed 23 mm apart in the same probe. The double probe characterization is accomplished in different studies, carried out in a dedicated test bench system, capable of reproducing a range of clinically relevant properties of the cardiovascular system.","PeriodicalId":399131,"journal":{"name":"2012 IEEE 2nd Portuguese Meeting in Bioengineering (ENBENG)","volume":"37 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE 2nd Portuguese Meeting in Bioengineering (ENBENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ENBENG.2012.6331386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Local pulse-wave velocity (PWV) is recognized as the simplest and most reproducible process of non-invasively assessing the vascular marker of arterial stiffness that allowing the risk of cardiovascular diseases to be determinate. Devices currently available for local PWV measurement have not yet been generalized to clinical practice since they require high technical expertise and most of them are limited in precision, due to the lack of reliable signal processing methods. This work describes a new type of probes, based on a piezoelectric sensor in different configurations, single probe and double probe. The principle of PWV measurement involves determination of the pulse transit time between the signals acquired simultaneously by both piezoelectric placed 23 mm apart in the same probe. The double probe characterization is accomplished in different studies, carried out in a dedicated test bench system, capable of reproducing a range of clinically relevant properties of the cardiovascular system.