{"title":"Research of remote backup protection functioning at the software and hardware complex RTDS","authors":"R. Isakov, A. Ferenets","doi":"10.1109/ICIEAM.2017.8076214","DOIUrl":null,"url":null,"abstract":"Remote backup protection is installed at the ends of the power line of 35–220 kV and provides detection of short-circuit on the low-voltage side of branch transformers. To support remote protection on 110 kV lines and above with two or multi-way power feed, it is mandatory to implement a three-stage remote protection from interphase short-circuit (phase-to-phase fault). To implement line protection with remote protection on a substation (in case of protection equipment operation failure, breaker failure on high voltage side and signal transfer device failure) seems to be more difficult comparing to a line short-circuit. It is related to limited possibilities of line protection sensitivity and, in many cases, operation parameters of a loaded line that define relay protection stage protection significantly exceed nominal power of the branch transformer.","PeriodicalId":428982,"journal":{"name":"2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEAM.2017.8076214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Remote backup protection is installed at the ends of the power line of 35–220 kV and provides detection of short-circuit on the low-voltage side of branch transformers. To support remote protection on 110 kV lines and above with two or multi-way power feed, it is mandatory to implement a three-stage remote protection from interphase short-circuit (phase-to-phase fault). To implement line protection with remote protection on a substation (in case of protection equipment operation failure, breaker failure on high voltage side and signal transfer device failure) seems to be more difficult comparing to a line short-circuit. It is related to limited possibilities of line protection sensitivity and, in many cases, operation parameters of a loaded line that define relay protection stage protection significantly exceed nominal power of the branch transformer.
软硬件复杂的RTDS中远程备份保护功能的研究
远程后备保护安装在35 ~ 220kv的电力线路末端,用于支路变压器低压侧短路检测。为了支持110千伏及以上双路或多路馈电线路的远程保护,必须实施三相相间短路(相对相故障)远程保护。与线路短路相比,在变电站实施远程保护的线路保护(在保护设备运行故障、高压侧断路器故障和信号传输装置故障的情况下)似乎更加困难。它与线路保护灵敏度的有限可能性有关,并且在许多情况下,负载线路的运行参数定义继电保护级保护大大超过分支变压器的标称功率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信