Xianlin Pan, I. Budovsky, V. Balakrishnan, Zhaomin Shi, Jiangtao Zhang
{"title":"Comparison amplitude error of current shunts at frequencies up to 100 kHz between NMIA and NIM","authors":"Xianlin Pan, I. Budovsky, V. Balakrishnan, Zhaomin Shi, Jiangtao Zhang","doi":"10.1109/CPEM49742.2020.9191931","DOIUrl":null,"url":null,"abstract":"This paper describes the comparison of amplitude error measurement in current shunts between NMIA and NIM at frequencies from 1 kHz to 100 kHz. A set of cage design shunts has been developed at NMIA and its amplitude errors determined using the ac-dc transfer setup at NMIA. At NIM a set of Inductive Current Dividers (ICDs) with ratios of 2:1, 5:1 and 10:1 has been developed to compare the amplitude errors of two shunts. Based on two totally different measurement methods, a number of current shunts have been compared at frequencies from 1 kHz to 100 kHz. The measurements of amplitude errors of current shunts yield excellent agreement within $10\\ \\mu \\mathrm{\\Omega}/\\mathrm{\\Omega}$ at frequencies up to 100 kHz and currents from 0.5 A to 10 A.","PeriodicalId":373216,"journal":{"name":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM49742.2020.9191931","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper describes the comparison of amplitude error measurement in current shunts between NMIA and NIM at frequencies from 1 kHz to 100 kHz. A set of cage design shunts has been developed at NMIA and its amplitude errors determined using the ac-dc transfer setup at NMIA. At NIM a set of Inductive Current Dividers (ICDs) with ratios of 2:1, 5:1 and 10:1 has been developed to compare the amplitude errors of two shunts. Based on two totally different measurement methods, a number of current shunts have been compared at frequencies from 1 kHz to 100 kHz. The measurements of amplitude errors of current shunts yield excellent agreement within $10\ \mu \mathrm{\Omega}/\mathrm{\Omega}$ at frequencies up to 100 kHz and currents from 0.5 A to 10 A.