E. Jowett, J. Currie, Kristopher A Pataky, Letitia Tudor
{"title":"Continuous Cycling, Shallow-Draft Sewage Siphons","authors":"E. Jowett, J. Currie, Kristopher A Pataky, Letitia Tudor","doi":"10.2139/ssrn.3874825","DOIUrl":null,"url":null,"abstract":"This paper describes experiments with novel shallow-draft, small dose, continuously cycling siphons for septic tank effluent that prime at low flows, and break at high flows, covering the full range of household flows (e.g., 5-20 L/min). Comparative test results for a commercially available, conventional ‘bell siphon’ are also provided for a wider range of flows of 1-35 L/min.","PeriodicalId":220342,"journal":{"name":"Materials Science Educator: Courses","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials Science Educator: Courses","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2139/ssrn.3874825","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper describes experiments with novel shallow-draft, small dose, continuously cycling siphons for septic tank effluent that prime at low flows, and break at high flows, covering the full range of household flows (e.g., 5-20 L/min). Comparative test results for a commercially available, conventional ‘bell siphon’ are also provided for a wider range of flows of 1-35 L/min.