{"title":"Stability Simulation of 150 kV Malang Power Grid","authors":"Arif Na, G. Fujita","doi":"10.17977/um049v4i2p01-08","DOIUrl":null,"url":null,"abstract":"This research describes the oscillation control based on a power system that takes the place of the traditional automatic voltage regulators for excitation control in addition to a multimachine power system. The design is built on equilibrium and a potent adaptive critic technique called decreasing time oscillation for each generator. The generators' local measurements serve as the sole basis for the feedback variables. For enhancing the dynamic performance and stability of the power grid under significant shocks that affected oscillation power stations, simulations on multi-machine power systems were shown to be effective.    ","PeriodicalId":285860,"journal":{"name":"Frontier Energy System and Power Engineering","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontier Energy System and Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17977/um049v4i2p01-08","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This research describes the oscillation control based on a power system that takes the place of the traditional automatic voltage regulators for excitation control in addition to a multimachine power system. The design is built on equilibrium and a potent adaptive critic technique called decreasing time oscillation for each generator. The generators' local measurements serve as the sole basis for the feedback variables. For enhancing the dynamic performance and stability of the power grid under significant shocks that affected oscillation power stations, simulations on multi-machine power systems were shown to be effective.    
马郎150kv电网稳定性仿真
本文介绍了在多机电力系统的基础上,以一种电力系统代替传统的自动调压器进行励磁控制的振荡控制方法。该设计是建立在平衡和一个有效的自适应批评技术称为减少时间振荡的每个发电机。发电机的局部测量作为反馈变量的唯一依据。为了提高振荡电站在重大冲击下电网的动态性能和稳定性,对多机电力系统进行仿真是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信