Pick-ups Counter Methodology for Broken Conductor Fault Detection

D. V. João, Hamilton G. B. Souza, M. A. Martins, K. Martins
{"title":"Pick-ups Counter Methodology for Broken Conductor Fault Detection","authors":"D. V. João, Hamilton G. B. Souza, M. A. Martins, K. Martins","doi":"10.1109/td43745.2022.9816972","DOIUrl":null,"url":null,"abstract":"The Power Electrical System is stricken randomly by many adversity cases. These situations, for example, are caused by weather instability, causing the electric grid to be affected by heavy rains, intense wind gusts, and lightning. In addition, traffic accidents, contact with objects on the network and irregular loads are unpredictable situations for the grid protection. Even though the robustness of the protection systems, many fault cases are still difficult to be detected. This is the case of a fault with a high contact impedance caused by a broken conductor. In this paper, it is proposed a solution to detect Broken Conductor (BC) fault considering the quantity of neutral current pick-ups during a High Impedance Fault (HIF). The methodology basically applies the SEF function monitoring in a time box window, where a pick-up counting is processed into that window. The results presented the analysis of 100 BC oscillographs cases, showing their applicability for HIF protection in the electrical power system.","PeriodicalId":241987,"journal":{"name":"2022 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/td43745.2022.9816972","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Power Electrical System is stricken randomly by many adversity cases. These situations, for example, are caused by weather instability, causing the electric grid to be affected by heavy rains, intense wind gusts, and lightning. In addition, traffic accidents, contact with objects on the network and irregular loads are unpredictable situations for the grid protection. Even though the robustness of the protection systems, many fault cases are still difficult to be detected. This is the case of a fault with a high contact impedance caused by a broken conductor. In this paper, it is proposed a solution to detect Broken Conductor (BC) fault considering the quantity of neutral current pick-ups during a High Impedance Fault (HIF). The methodology basically applies the SEF function monitoring in a time box window, where a pick-up counting is processed into that window. The results presented the analysis of 100 BC oscillographs cases, showing their applicability for HIF protection in the electrical power system.
断线故障检测的拾取计数器方法
电力系统受到许多突发事件的随机冲击。例如,这些情况是由天气不稳定引起的,导致电网受到暴雨、强风和闪电的影响。此外,交通事故、与网内物体接触、负荷不规律等都是电网保护不可预测的情况。尽管保护系统具有较强的鲁棒性,但仍有许多故障难以检测到。这是由导体断裂引起的高接触阻抗故障的情况。本文提出了一种考虑高阻抗故障中性点拾取量的断线故障检测方法。该方法基本上在时间盒窗口中应用SEF函数监控,在该窗口中处理拾取计数。通过对100个BC示波器的实例分析,证明了该示波器在电力系统高频保护中的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信