Mapping size distributions of parenteral fluorocarbon emulsions by a novel method of centrifugal sedimentation followed by densitometry.

S P Apte, S J Turco
{"title":"Mapping size distributions of parenteral fluorocarbon emulsions by a novel method of centrifugal sedimentation followed by densitometry.","authors":"S P Apte,&nbsp;S J Turco","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A novel method for characterization of size distributions of parenteral fluorocarbon emulsions is described. Prepared emulsions were centrifuged to sediment droplets above predetermined diameters out of a known supernatant sample volume using the Bostok-Stoke's equation. Centrifugation times may be calculated using centrifuge parameters and physical properties of the fluorocarbon oil phase and the dispersion medium. The fluorocarbon content of the supernatant sample volume at successive centrifugation times was determined both by densitometry and by Gas Chromatography. A close correlation was found between the two methods. The density data was processed and converted into a volume distribution histogram by means of a program written in BASIC. The speed, simplicity of use, non reliance on costly equipment and good correlation to absolute particle counting methods makes the density method suitable for submicron size characterization.</p>","PeriodicalId":16667,"journal":{"name":"Journal of parenteral science and technology : a publication of the Parenteral Drug Association","volume":"46 6","pages":"233-8"},"PeriodicalIF":0.0000,"publicationDate":"1992-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of parenteral science and technology : a publication of the Parenteral Drug Association","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A novel method for characterization of size distributions of parenteral fluorocarbon emulsions is described. Prepared emulsions were centrifuged to sediment droplets above predetermined diameters out of a known supernatant sample volume using the Bostok-Stoke's equation. Centrifugation times may be calculated using centrifuge parameters and physical properties of the fluorocarbon oil phase and the dispersion medium. The fluorocarbon content of the supernatant sample volume at successive centrifugation times was determined both by densitometry and by Gas Chromatography. A close correlation was found between the two methods. The density data was processed and converted into a volume distribution histogram by means of a program written in BASIC. The speed, simplicity of use, non reliance on costly equipment and good correlation to absolute particle counting methods makes the density method suitable for submicron size characterization.

用离心沉降法和密度测定法绘制注射用氟碳乳剂的尺寸分布。
描述了一种表征注射用氟碳乳剂粒径分布的新方法。利用Bostok-Stoke方程,将制备好的乳剂从已知的上清样品体积中离心到大于预定直径的沉淀物液滴。离心次数可根据离心机参数和氟碳油相及分散介质的物理性质计算。用密度法和气相色谱法测定连续离心次数下上清样品体积的氟碳含量。两种方法之间存在密切的相关性。利用BASIC编写的程序对密度数据进行处理并转换成体积分布直方图。密度法的速度快,使用简单,不依赖昂贵的设备,与绝对粒子计数方法有很好的相关性,使得密度法适用于亚微米尺寸的表征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信