Detection of Leak Site in Sloped Transmission Lines

M. Derakhshan, M. Haeri
{"title":"Detection of Leak Site in Sloped Transmission Lines","authors":"M. Derakhshan, M. Haeri","doi":"10.1109/CEIT.2018.8751847","DOIUrl":null,"url":null,"abstract":"In this paper a method is presented to estimate the leak site in sloped transmission lines using a closed solution of the transmission line equations and linear observer. First, the equations are solved for a constant input state, and then the initial estimation of the leak site is presented for variable input state and the leak and pressure coefficient in the leak site is determined with the help of equations obtained from the closed solution using the estimation of the leak site. Then, the nonlinear model is determined by discretizing the transmission line equations with respect to the site variable considering a floating point for the leak site in the observer, designing a linear observer using the initial estimation obtained from the closed solution, and linearizing the observers equations at the obtained point.","PeriodicalId":357613,"journal":{"name":"2018 6th International Conference on Control Engineering & Information Technology (CEIT)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 6th International Conference on Control Engineering & Information Technology (CEIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIT.2018.8751847","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper a method is presented to estimate the leak site in sloped transmission lines using a closed solution of the transmission line equations and linear observer. First, the equations are solved for a constant input state, and then the initial estimation of the leak site is presented for variable input state and the leak and pressure coefficient in the leak site is determined with the help of equations obtained from the closed solution using the estimation of the leak site. Then, the nonlinear model is determined by discretizing the transmission line equations with respect to the site variable considering a floating point for the leak site in the observer, designing a linear observer using the initial estimation obtained from the closed solution, and linearizing the observers equations at the obtained point.
倾斜输电线路泄漏部位的检测
本文提出了一种利用输电线路方程的封闭解和线性观测器估计倾斜输电线路泄漏位置的方法。首先求解恒定输入状态下的方程,然后给出变输入状态下泄漏点的初始估计,利用泄漏点估计得到的封闭解得到的方程确定泄漏点的泄漏系数和压力系数。然后,考虑观测点泄漏位置为浮点,将传输线方程相对于位置变量进行离散化,利用封闭解的初始估计设计线性观测器,并将观测点方程线性化,从而确定非线性模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信