Performance assessment of islanding detection using complex wavelet in a three-phase utility interactive inverter system

S. Pinto, G. Panda
{"title":"Performance assessment of islanding detection using complex wavelet in a three-phase utility interactive inverter system","authors":"S. Pinto, G. Panda","doi":"10.1109/APPEEC.2017.8308926","DOIUrl":null,"url":null,"abstract":"This paper focuses on the performance assessment of a complex wavelet transform (CWT) based passive islanding detection technique in a three-phase utility interactive inverter system under various transient scenarios such as faults, unbalance and distorted grid voltage. It is envisaged in various litterers that passive detection techniques have a larger nondetection zone (NDZ), whereas active islanding detection techniques have smaller NDZ. But, active detection scheme deteriorates the power quality (PQ) of a system. In this study, a CWT based detection scheme is used to obtain time-frequency localization of the islanding situation as well as PQ disturbances in a DG interfacing inverter system. The system is simulated using MATLAB/SIMULINK platform for demonstrating the effectiveness and superior performance of CWT based detection technique compared to conventional db8 wavelet transform (WT) under various perturbations.","PeriodicalId":247669,"journal":{"name":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"86 13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2017.8308926","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper focuses on the performance assessment of a complex wavelet transform (CWT) based passive islanding detection technique in a three-phase utility interactive inverter system under various transient scenarios such as faults, unbalance and distorted grid voltage. It is envisaged in various litterers that passive detection techniques have a larger nondetection zone (NDZ), whereas active islanding detection techniques have smaller NDZ. But, active detection scheme deteriorates the power quality (PQ) of a system. In this study, a CWT based detection scheme is used to obtain time-frequency localization of the islanding situation as well as PQ disturbances in a DG interfacing inverter system. The system is simulated using MATLAB/SIMULINK platform for demonstrating the effectiveness and superior performance of CWT based detection technique compared to conventional db8 wavelet transform (WT) under various perturbations.
基于复小波的三相公用事业交互式逆变系统孤岛检测性能评价
研究了一种基于复小波变换(CWT)的无源孤岛检测技术在三相电力交互式逆变系统故障、不平衡和电网电压畸变等多种暂态情况下的性能评估。在各种凋落物中,设想被动探测技术具有较大的非探测区(NDZ),而主动孤岛探测技术具有较小的NDZ。但是,主动检测方案会降低系统的电能质量(PQ)。在本研究中,采用基于CWT的检测方案来获得DG接口逆变器系统中孤岛情况和PQ干扰的时频定位。在MATLAB/SIMULINK平台上对该系统进行了仿真,验证了基于CWT的检测技术在各种扰动下的有效性和优于传统db8小波变换(WT)的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信