{"title":"The comparison of size-specific dose estimate in CT examination based on head and body PMMA phantom","authors":"Mohd Hanafi Ali, C. Anam, F. Haryanto, G. Dougherty","doi":"10.14710/JPA.V1I1.3905","DOIUrl":null,"url":null,"abstract":"Nowadays, a dose estimate for individual patients undergoing CT examination is carried out using the metric of size-specific dose estimate (SSDE), which is calculated by multiplying a volume CT dose index (CTDIvol) and a correction factor that is a function of patient size. Two CTDIvol values are based on head and body PMMA phantoms. There are also two values of correction factors (k), both for head and body PMMA phantoms. The purpose of this study was to compare the SSDE values calculated using head and body PMMA phantoms with their corresponding correction factors (k). The CTDIvol values were derived from the ImPACT 1.04 software for 12 CT scanners: Sensation 4, Sensation 16, Sensation 64, Light Speed, Light Speed 16, Light Speed VCT, Secura, Brilliance 16, Brilliance 64, Asteion Dual, Aquilion 4, and Aquilion 16. The size of the patients who underwent CT examination was characterized by a water-equivalent diameter (Dw) from 10 cm to 45 cm. The results indicated that the differences in SSDE values based on head and body CTDIvol were within 20%. Thus, the SSDE value can be calculated using the head or body CTDIvol bases with corresponding k value.","PeriodicalId":280868,"journal":{"name":"Journal of Physics and Its Applications","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physics and Its Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14710/JPA.V1I1.3905","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Nowadays, a dose estimate for individual patients undergoing CT examination is carried out using the metric of size-specific dose estimate (SSDE), which is calculated by multiplying a volume CT dose index (CTDIvol) and a correction factor that is a function of patient size. Two CTDIvol values are based on head and body PMMA phantoms. There are also two values of correction factors (k), both for head and body PMMA phantoms. The purpose of this study was to compare the SSDE values calculated using head and body PMMA phantoms with their corresponding correction factors (k). The CTDIvol values were derived from the ImPACT 1.04 software for 12 CT scanners: Sensation 4, Sensation 16, Sensation 64, Light Speed, Light Speed 16, Light Speed VCT, Secura, Brilliance 16, Brilliance 64, Asteion Dual, Aquilion 4, and Aquilion 16. The size of the patients who underwent CT examination was characterized by a water-equivalent diameter (Dw) from 10 cm to 45 cm. The results indicated that the differences in SSDE values based on head and body CTDIvol were within 20%. Thus, the SSDE value can be calculated using the head or body CTDIvol bases with corresponding k value.
基于头部和身体PMMA幻像的CT检查中大小特异性剂量估计的比较
目前,对接受CT检查的个体患者的剂量估计是使用尺寸特异性剂量估计(SSDE)度量进行的,其计算方法是将体积CT剂量指数(CTDIvol)与作为患者尺寸函数的校正因子相乘。两个CTDIvol值是基于头部和身体PMMA幻象。对于头部和身体的PMMA幻影,也有两个校正因子(k)的值。本研究的目的是比较使用头部和身体PMMA幻影计算的SSDE值及其相应的校正因子(k)。CTDIvol值来自ImPACT 1.04软件,适用于12台CT扫描仪:Sensation 4、Sensation 16、Sensation 64、Light Speed、Light Speed 16、Light Speed VCT、Secura、Brilliance 16、Brilliance 64、Asteion Dual、Aquilion 4和Aquilion 16。接受CT检查的患者的大小以水当量直径(Dw)为特征,从10厘米到45厘米。结果表明,基于头部和身体CTDIvol的SSDE值差异在20%以内。因此,可以使用具有相应k值的头部或身体CTDIvol基来计算SSDE值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信