{"title":"Auto tuning of parameters and magnetization curve of an induction motor at standstill","authors":"C. Sukhapap, S. Sangwongwanich","doi":"10.1109/ICIT.2002.1189871","DOIUrl":null,"url":null,"abstract":"Determination of motor parameters using the conventional no-load and locked-rotor tests are not applicable in many situations due to the difficulty in removing the mechanical load. In this paper, an off-line parameter auto-tuning method for an induction motor at standstill using a PWM inverter is investigated. Each parameter of the motor including the magnetization curve are identified by the injection of an appropriate stator voltage or current of a predetermined pattern whilst the motor is kept at standstill. The dead-time effect and device voltage drop are taken into consideration in the identification procedure. Also the recursive least-square algorithm is adopted in the calculation to reduce the effect of noises.","PeriodicalId":344984,"journal":{"name":"2002 IEEE International Conference on Industrial Technology, 2002. IEEE ICIT '02.","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE International Conference on Industrial Technology, 2002. IEEE ICIT '02.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2002.1189871","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17
Abstract
Determination of motor parameters using the conventional no-load and locked-rotor tests are not applicable in many situations due to the difficulty in removing the mechanical load. In this paper, an off-line parameter auto-tuning method for an induction motor at standstill using a PWM inverter is investigated. Each parameter of the motor including the magnetization curve are identified by the injection of an appropriate stator voltage or current of a predetermined pattern whilst the motor is kept at standstill. The dead-time effect and device voltage drop are taken into consideration in the identification procedure. Also the recursive least-square algorithm is adopted in the calculation to reduce the effect of noises.