Barehand bonding arc electrical characteristics test

K. Cornish
{"title":"Barehand bonding arc electrical characteristics test","authors":"K. Cornish","doi":"10.1109/TDCLLM.1993.316250","DOIUrl":null,"url":null,"abstract":"In July, 1991, the California Department of Occupational Safety and Health issued a variance to Pacific Gas and Electric Company to allow the use of barehand work procedures on 230 kV and 500 kV transmission lines. There were requirements and restrictions imposed upon PG&E for issuing and maintaining this variance permit. One such requirement was that PG&E institute a program to evaluate and monitor the magnetic field health issue as it relates to the use of barehand techniques. The intent was to compare the electromagnetic exposure levels of barehand work procedures to other hot stick, live line techniques that PG&E utilizes. As part of the monitoring program and information gathering process, the Pacific Gas and Electric Company's Joint Union/Management Barehand Committee requested that electrical characteristic tests be performed on the arc that is obtained when performing the procedure of bonding onto or removing the bonding connection from an energized transmission line conductor. The purpose of the test was two-fold: (1) to characterize the energy in the bonding arc as defined in terms of power density, and (2) to compare measured arc power density levels with the protection guideline limits established in American National Standard Institute (ANSI) C95.1-1991 Standard \"American National Standard Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields (300 kHz-100 GHz)\".<<ETX>>","PeriodicalId":198668,"journal":{"name":"Proceedings of ESMO '93. IEEE 6th International Conference on Transmission and Distribution Construction and Live-Line Maintenance","volume":"34 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of ESMO '93. IEEE 6th International Conference on Transmission and Distribution Construction and Live-Line Maintenance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDCLLM.1993.316250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In July, 1991, the California Department of Occupational Safety and Health issued a variance to Pacific Gas and Electric Company to allow the use of barehand work procedures on 230 kV and 500 kV transmission lines. There were requirements and restrictions imposed upon PG&E for issuing and maintaining this variance permit. One such requirement was that PG&E institute a program to evaluate and monitor the magnetic field health issue as it relates to the use of barehand techniques. The intent was to compare the electromagnetic exposure levels of barehand work procedures to other hot stick, live line techniques that PG&E utilizes. As part of the monitoring program and information gathering process, the Pacific Gas and Electric Company's Joint Union/Management Barehand Committee requested that electrical characteristic tests be performed on the arc that is obtained when performing the procedure of bonding onto or removing the bonding connection from an energized transmission line conductor. The purpose of the test was two-fold: (1) to characterize the energy in the bonding arc as defined in terms of power density, and (2) to compare measured arc power density levels with the protection guideline limits established in American National Standard Institute (ANSI) C95.1-1991 Standard "American National Standard Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields (300 kHz-100 GHz)".<>
徒手焊弧电特性试验
1991年7月,加州职业安全与健康部门向太平洋天然气和电力公司发布了一项变更,允许在230千伏和500千伏输电线路上使用徒手作业程序。对于PG&E签发和维护这种变更许可,有一些要求和限制。其中一项要求是PG&E制定一个方案来评估和监测与使用徒手技术有关的磁场健康问题。目的是比较徒手作业程序的电磁暴露水平与PG&E使用的其他热棒、带电线路技术。作为监测计划和信息收集过程的一部分,太平洋天然气和电力公司联合联盟/管理赤手委员会要求对在通电输电线路导体上进行粘接或拆除粘接连接时获得的电弧进行电气特性测试。测试的目的有两方面:(1)根据功率密度来描述键合电弧中的能量,(2)将测量的电弧功率密度水平与美国国家标准协会(ANSI) C95.1-1991标准“人体暴露于射频电磁场(300 kHz-100 GHz)的美国国家标准安全水平”中建立的保护指导限值进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信