Performance Analysis of the Distance Relay Characteristics in a Compensated Transmission Line

M. Al-Momani, A. Hatmi, Seba F. Al-Gharaibeh
{"title":"Performance Analysis of the Distance Relay Characteristics in a Compensated Transmission Line","authors":"M. Al-Momani, A. Hatmi, Seba F. Al-Gharaibeh","doi":"10.18280/ejee.230304","DOIUrl":null,"url":null,"abstract":"Received: 2 November 2020 Accepted: 18 April 2021 The present work investigates the effect of the FACTS devices on distance relay operation. FACTS devices have different advantages in power system performance, stability, and load ability. In this paper, FACTS technologies' effect on the distance protective relay is presented using the measured impedance between the fault location and the relaying point. Different factors and parameters are changed to see their impacts on the studied system. It is shown that the measured impedance is affected by the presence of the FACTS devices depending on its type (series, parallel, and hybrid), fault location, and the operation point of the FACTS device. The analyses present that the shunt FACTS devices' effect may cause overreach problem to the relay; however, series FACTS devices may cause under reach problems in distance characteristics. MATLAB 2019b does the simulation test; the results of the simulation proved the mathematical analysis. The numerical analysis in this paper may be used for researchers in fault analysis and protection coordinators.","PeriodicalId":340029,"journal":{"name":"European Journal of Electrical Engineering","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18280/ejee.230304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Received: 2 November 2020 Accepted: 18 April 2021 The present work investigates the effect of the FACTS devices on distance relay operation. FACTS devices have different advantages in power system performance, stability, and load ability. In this paper, FACTS technologies' effect on the distance protective relay is presented using the measured impedance between the fault location and the relaying point. Different factors and parameters are changed to see their impacts on the studied system. It is shown that the measured impedance is affected by the presence of the FACTS devices depending on its type (series, parallel, and hybrid), fault location, and the operation point of the FACTS device. The analyses present that the shunt FACTS devices' effect may cause overreach problem to the relay; however, series FACTS devices may cause under reach problems in distance characteristics. MATLAB 2019b does the simulation test; the results of the simulation proved the mathematical analysis. The numerical analysis in this paper may be used for researchers in fault analysis and protection coordinators.
补偿传输线中距离继电器特性的性能分析
本文研究了FACTS装置对距离继电器运行的影响。FACTS设备在电力系统性能、稳定性和负载能力方面具有不同的优势。本文通过测量故障点与继电点之间的阻抗,阐述了FACTS技术对距离保护继电器的影响。改变不同的因素和参数,观察它们对研究系统的影响。结果表明,事实器件的存在对测量阻抗的影响取决于其类型(串联、并联和混合)、故障位置和事实器件的工作点。分析认为,并联FACTS器件的作用可能会引起继电器的过伸问题;然而,系列FACTS器件在距离特性方面可能会导致达不到的问题。用MATLAB 2019b进行仿真测试;仿真结果验证了数学分析的正确性。本文的数值分析可以为故障分析和保护协调的研究人员提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信