Crystal defects and charge collection in CdTe-based x- and gamma-ray detectors

O. Maslyanchuk, I. Fodchuk, M. Solovan, I. Boledzyuk, A. Kuzmin, V. Gnatyuk, T. Aoki
{"title":"Crystal defects and charge collection in CdTe-based x- and gamma-ray detectors","authors":"O. Maslyanchuk, I. Fodchuk, M. Solovan, I. Boledzyuk, A. Kuzmin, V. Gnatyuk, T. Aoki","doi":"10.1117/12.2615504","DOIUrl":null,"url":null,"abstract":"The defects structure, charge collection, and detection efficiency of the Ni(NiO)/p-CdTe/Au/Cu Schottky-diode detector have been investigated. The spectroscopic properties of the obtained heterostructures have been studied experimentally and analyzed theoretically. The optimal reverse bias voltage for higher performance of the detectors under study was determined. The reasons of poor charge collection in the detectors and low detection efficiency of photons emitted by an 241Am (59.5 keV) radioisotope have been established and discussed. The techniques of increasing the functional parameters of Ni(NiO)/p-CdTe/Au/Cu Schottky diodes have the investigated and the optimal ways for improvement of the detector performance have been formulated.","PeriodicalId":250235,"journal":{"name":"International Conference on Correlation Optics","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Correlation Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2615504","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The defects structure, charge collection, and detection efficiency of the Ni(NiO)/p-CdTe/Au/Cu Schottky-diode detector have been investigated. The spectroscopic properties of the obtained heterostructures have been studied experimentally and analyzed theoretically. The optimal reverse bias voltage for higher performance of the detectors under study was determined. The reasons of poor charge collection in the detectors and low detection efficiency of photons emitted by an 241Am (59.5 keV) radioisotope have been established and discussed. The techniques of increasing the functional parameters of Ni(NiO)/p-CdTe/Au/Cu Schottky diodes have the investigated and the optimal ways for improvement of the detector performance have been formulated.
基于cdte的x射线和伽马射线探测器中的晶体缺陷和电荷收集
研究了Ni(NiO)/p-CdTe/Au/Cu肖特基二极管探测器的缺陷结构、电荷收集和探测效率。对所得异质结构的光谱特性进行了实验研究和理论分析。确定了提高探测器性能的最佳反向偏置电压。建立并讨论了241Am (59.5 keV)放射性同位素发射的光子在探测器中电荷收集不良和探测效率低的原因。研究了提高Ni(NiO)/p-CdTe/Au/Cu肖特基二极管功能参数的技术,并制定了提高探测器性能的最佳途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信