{"title":"Impella Device is Superior to an Intra-Aortic Balloon Pump in Cardiogenic Shock","authors":"Khan Muhammad Zubair, F. Sona, Hyman Richard","doi":"10.23937/2643-3966/1710040","DOIUrl":null,"url":null,"abstract":"A Percutaneous assist device is commonly used in cardiogenic shock to improve hemodynamics. The Impella provided superior hemodynamic support in the ISARSHOCK study compared with an intra-aortic balloon pump (IABP), with no change in clinical outcome. In this trial, the IABP was used in one group, and the Impella was placed in a comparator group. We present a case in which the hemodynamics of cardiogenic shock was assessed in the same patient after IABP and after Impella placement. In our case, the hemodynamics improved after Impella placement and removal of IABP. *Corresponding author: Richard Hyman, MD, Department of Medicine, St. Mary Medical Center, 1201 NewtownLanghorne Rd, Langhorne, PA 19047, USA, Tel: +1-215-750-7000 Check for updates","PeriodicalId":170730,"journal":{"name":"International Archives of Cardiovascular Diseases","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Archives of Cardiovascular Diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23937/2643-3966/1710040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A Percutaneous assist device is commonly used in cardiogenic shock to improve hemodynamics. The Impella provided superior hemodynamic support in the ISARSHOCK study compared with an intra-aortic balloon pump (IABP), with no change in clinical outcome. In this trial, the IABP was used in one group, and the Impella was placed in a comparator group. We present a case in which the hemodynamics of cardiogenic shock was assessed in the same patient after IABP and after Impella placement. In our case, the hemodynamics improved after Impella placement and removal of IABP. *Corresponding author: Richard Hyman, MD, Department of Medicine, St. Mary Medical Center, 1201 NewtownLanghorne Rd, Langhorne, PA 19047, USA, Tel: +1-215-750-7000 Check for updates
经皮辅助装置常用于心源性休克以改善血流动力学。在ISARSHOCK研究中,与主动脉内球囊泵(IABP)相比,Impella提供了更好的血流动力学支持,临床结果没有变化。在本试验中,IABP作为一组,Impella作为对照组。我们提出了一个病例,在IABP和Impella放置后,对同一患者的心源性休克的血流动力学进行了评估。在我们的病例中,在植入和移除IABP后,血流动力学得到改善。*通讯作者:Richard Hyman,医学博士,圣玛丽医疗中心医学系,1201 NewtownLanghorne Rd, Langhorne, PA 19047, USA, Tel: +1-215-750-7000查看最新情况