Exergetic Performance Comparison between Steam-Heated and Closed-Cycle Heat Pump Applications for Lumber-Drying

Sevgi Erzen, E. Açıkkalp, A. Hepbasli
{"title":"Exergetic Performance Comparison between Steam-Heated and Closed-Cycle Heat Pump Applications for Lumber-Drying","authors":"Sevgi Erzen, E. Açıkkalp, A. Hepbasli","doi":"10.1109/IYCE45807.2019.8991582","DOIUrl":null,"url":null,"abstract":"Exergy analysis is a very strong method to evaluate the performance of energy-related systems from the thermodynamic point of view. Because, unlike the energy analysis, exergy analysis enables to determine the location and amount of the irreversibilities, which cause inefficiencies in the system and its components. In this study, the results of exergetic performances of two various heating systems, namely a steam- heated system and a closed-cycle heat pump system, for lumber- drying are considered and compared for the first time to the best of the authors' knowledge. The thermodynamic inefficiencies of the system components are evaluated in parts. The results show that the condenser in the closed-cycle heat pump is the most important system component for efficiency improvement. By comparison, various investigators reported in their similar studies that exergy efficiency values varied between 76-97%.","PeriodicalId":226881,"journal":{"name":"2019 7th International Youth Conference on Energy (IYCE)","volume":"163 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 7th International Youth Conference on Energy (IYCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IYCE45807.2019.8991582","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Exergy analysis is a very strong method to evaluate the performance of energy-related systems from the thermodynamic point of view. Because, unlike the energy analysis, exergy analysis enables to determine the location and amount of the irreversibilities, which cause inefficiencies in the system and its components. In this study, the results of exergetic performances of two various heating systems, namely a steam- heated system and a closed-cycle heat pump system, for lumber- drying are considered and compared for the first time to the best of the authors' knowledge. The thermodynamic inefficiencies of the system components are evaluated in parts. The results show that the condenser in the closed-cycle heat pump is the most important system component for efficiency improvement. By comparison, various investigators reported in their similar studies that exergy efficiency values varied between 76-97%.
蒸汽加热热泵与闭式循环热泵在木材干燥中的性能比较
从热力学的角度来看,火用分析是评价与能源有关的系统性能的一种强有力的方法。因为,与能量分析不同,能量分析能够确定不可逆性的位置和数量,这些不可逆性会导致系统及其组件的低效率。在这项研究中,考虑了两种不同的加热系统,即蒸汽加热系统和闭式循环热泵系统,木材干燥的火用性能的结果,并在作者所知的范围内第一次进行了比较。系统组件的热力学效率低下被部分地评估。结果表明,冷凝器是提高闭式循环热泵效率最重要的系统部件。相比之下,不同的研究者在他们类似的研究中报告说,火用效率值在76-97%之间变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信