{"title":"Analysis of data reliability and stability in HR-SDN communication module","authors":"Dong-Hee Choi, Jinsuh Shin, H. Park","doi":"10.1117/12.784106","DOIUrl":null,"url":null,"abstract":"Profibus is open industrial communication system for wide range of applications in manufacturing and process automation. In Profibus, FDL service use to need hard real-time system. In these systems required data reliability and stability and real-time feature. Profibus fieldbus networks used in many industrial fields because of it supports real-time industrial communication. So we analyze of data reliability and stabilization in profibus network. In this paper, there was to a station for communication which uses FDL from in the communication module which is used a data transfer possibility at once, and from communication period (ex. 10ms) it analyzed the system effect which it follows in transmission lag occurrence element and a data transfer error ratio it analyzed. Like this analytical result it led and there were from transmission for reliability and data stability they confirmed to HR-SDN communication modules and a guarantee yes or no. In this paper, we try to analysis of transmission delay ability for satisfaction data reliability and stability in specific system, which requested real-time feature. And, we analysis system reconstruction time and data delay time according to data/token packet loss. Packet-error occur physical layer in Profibus. As a result of above analysis, we propose method of enhancement of reliability in system which requested system reliability and stability. And, we confirm proposed method.","PeriodicalId":250590,"journal":{"name":"ICMIT: Mechatronics and Information Technology","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICMIT: Mechatronics and Information Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.784106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Profibus is open industrial communication system for wide range of applications in manufacturing and process automation. In Profibus, FDL service use to need hard real-time system. In these systems required data reliability and stability and real-time feature. Profibus fieldbus networks used in many industrial fields because of it supports real-time industrial communication. So we analyze of data reliability and stabilization in profibus network. In this paper, there was to a station for communication which uses FDL from in the communication module which is used a data transfer possibility at once, and from communication period (ex. 10ms) it analyzed the system effect which it follows in transmission lag occurrence element and a data transfer error ratio it analyzed. Like this analytical result it led and there were from transmission for reliability and data stability they confirmed to HR-SDN communication modules and a guarantee yes or no. In this paper, we try to analysis of transmission delay ability for satisfaction data reliability and stability in specific system, which requested real-time feature. And, we analysis system reconstruction time and data delay time according to data/token packet loss. Packet-error occur physical layer in Profibus. As a result of above analysis, we propose method of enhancement of reliability in system which requested system reliability and stability. And, we confirm proposed method.