Loss of Cement-Bone Interlock during In Vivo Service of Total Knee Replacements

Jacklyn R. Goodheart, Mark A. Miller, K. Mann
{"title":"Loss of Cement-Bone Interlock during In Vivo Service of Total Knee Replacements","authors":"Jacklyn R. Goodheart, Mark A. Miller, K. Mann","doi":"10.1109/NEBEC.2013.23","DOIUrl":null,"url":null,"abstract":"The morphology of the cement-bone interface from total knee replacements was investigated as a function of time in service. Ten post-mortem retrievals and one lab-prepared specimen were sectioned and imaged with high-resolution microscopy. Stereology was used to quantify contact fraction and interdigitation depth. The results show that loss of fixation occurs by resorption of trabeculae that interlock with cement. This occurs early after implantation (1-2 years). Donor bones with better initial interlock maintain interlock better in the short term. The results suggest that loss of interlock between cement and bone could be a factor contributing to aseptic loosening.","PeriodicalId":153112,"journal":{"name":"2013 39th Annual Northeast Bioengineering Conference","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 39th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBEC.2013.23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The morphology of the cement-bone interface from total knee replacements was investigated as a function of time in service. Ten post-mortem retrievals and one lab-prepared specimen were sectioned and imaged with high-resolution microscopy. Stereology was used to quantify contact fraction and interdigitation depth. The results show that loss of fixation occurs by resorption of trabeculae that interlock with cement. This occurs early after implantation (1-2 years). Donor bones with better initial interlock maintain interlock better in the short term. The results suggest that loss of interlock between cement and bone could be a factor contributing to aseptic loosening.
全膝关节置换术中骨水泥联锁缺失
研究了全膝关节置换术后水泥-骨界面的形态与使用时间的关系。10个死后标本和一个实验室制备的标本被切片并用高分辨率显微镜成像。体视学用于量化接触分数和指间深度。结果表明,骨小梁与骨水泥互锁导致了骨小梁的吸收。这发生在植入后早期(1-2年)。初始联锁较好的供体骨在短期内维持联锁较好。结果表明骨水泥与骨之间联锁的丧失可能是导致无菌性松动的一个因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信