Kahina Louadj, Fethi Demim, A. Nemra, M. Aidène, P. Marthon, Hocine Iddir
{"title":"Optimization of Electricity Consumption in a building","authors":"Kahina Louadj, Fethi Demim, A. Nemra, M. Aidène, P. Marthon, Hocine Iddir","doi":"10.1109/CoDIT.2018.8394953","DOIUrl":null,"url":null,"abstract":"The main objective of an energy regulation of a building is to maintain internal thermal comfort, as well as minimize energy consumption, or reduce the peak of electrical consumption. The dynamic programming has been used to minimize a cost function, accounting for a high peak electricity tariff, under constraints related to comfort (minimal temperature, maximal temperature variation) and the maximum heating power. The proposed energy management consists in over-heating the building during the hours before the peak knowing in advance the weather, occupation and internal gains for the day. The method has been tested in a case study corresponding to a house of a four-person family with performance levels: high construction and poorly insulated old house.","PeriodicalId":128011,"journal":{"name":"2018 5th International Conference on Control, Decision and Information Technologies (CoDIT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 5th International Conference on Control, Decision and Information Technologies (CoDIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CoDIT.2018.8394953","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The main objective of an energy regulation of a building is to maintain internal thermal comfort, as well as minimize energy consumption, or reduce the peak of electrical consumption. The dynamic programming has been used to minimize a cost function, accounting for a high peak electricity tariff, under constraints related to comfort (minimal temperature, maximal temperature variation) and the maximum heating power. The proposed energy management consists in over-heating the building during the hours before the peak knowing in advance the weather, occupation and internal gains for the day. The method has been tested in a case study corresponding to a house of a four-person family with performance levels: high construction and poorly insulated old house.