{"title":"A comparison of LIN and TTP/A","authors":"Hermann Kopetz, Wilfried Elmenreich, C. Mack","doi":"10.1109/WFCS.2000.882539","DOIUrl":null,"url":null,"abstract":"The paper compares two novel field-bus protocols for low-cost single-chip smart sensor and actuator nodes, LIN and TTP/A. Both protocols are central-master UART protocols, where the master with its precise oscillator establishes the stable time-base required by the slaves to synchronize their imprecise on-chip oscillators. While LIN provides the basic services needed for real-time communication, the TTP/A standard additionally specifies an interface-file system to perform on-line configuration, diagnostics and maintenance of smart sensor nodes. With TTP/A it is thus possible to produce preprogrammed simple transducer nodes or generic smart transducer nodes that can be configured dynamically to the given application requirements.","PeriodicalId":112914,"journal":{"name":"2000 IEEE International Workshop on Factory Communication Systems. Proceedings (Cat. No.00TH8531)","volume":"315 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"27","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE International Workshop on Factory Communication Systems. Proceedings (Cat. No.00TH8531)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WFCS.2000.882539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 27
Abstract
The paper compares two novel field-bus protocols for low-cost single-chip smart sensor and actuator nodes, LIN and TTP/A. Both protocols are central-master UART protocols, where the master with its precise oscillator establishes the stable time-base required by the slaves to synchronize their imprecise on-chip oscillators. While LIN provides the basic services needed for real-time communication, the TTP/A standard additionally specifies an interface-file system to perform on-line configuration, diagnostics and maintenance of smart sensor nodes. With TTP/A it is thus possible to produce preprogrammed simple transducer nodes or generic smart transducer nodes that can be configured dynamically to the given application requirements.