{"title":"Detection of biotin-streptavidin interaction using RF interdigitated capacitive cavity","authors":"P. Porwal, Syed Azeemuddin, P. Bhimalapuram, T. Sau","doi":"10.1109/IMARC.2016.7939624","DOIUrl":null,"url":null,"abstract":"In this paper, biotin streptavidin interaction has been sensed at microwave frequencies with the help of designed sensor. It takes advantage of two pole filter topology where interdigitated capacitor (IDC) is used as a coupling zone between resonators for higher sensitivity. Due to permittivity change of biotin streptavidin combination, shift in resonant frequency arise whereas due to conductivity, magnitude of reflection coefficient changes. The frequency range of 10 GHz − 25 GHz (γ- dispersion region) is used as it is effective for label free analysis of biotin streptavidin. Due to homogeneous E-field between the fingers of IDC, placement position of biotin-streptavidin will not affect the sensitivity. Significant frequency shifts as high as 19 MHz, 45 MHz and 70 MHz are observed for concentrations as low as 10 ng/ml, 20 ng/ml and 30 ng/ml of biotin-streptavidin respectively. Simulation results suggest that proposed biosensor is sensitive even for concentration of 5 ng/ml of sample.","PeriodicalId":341661,"journal":{"name":"2016 IEEE MTT-S International Microwave and RF Conference (IMaRC)","volume":"91 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE MTT-S International Microwave and RF Conference (IMaRC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMARC.2016.7939624","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

In this paper, biotin streptavidin interaction has been sensed at microwave frequencies with the help of designed sensor. It takes advantage of two pole filter topology where interdigitated capacitor (IDC) is used as a coupling zone between resonators for higher sensitivity. Due to permittivity change of biotin streptavidin combination, shift in resonant frequency arise whereas due to conductivity, magnitude of reflection coefficient changes. The frequency range of 10 GHz − 25 GHz (γ- dispersion region) is used as it is effective for label free analysis of biotin streptavidin. Due to homogeneous E-field between the fingers of IDC, placement position of biotin-streptavidin will not affect the sensitivity. Significant frequency shifts as high as 19 MHz, 45 MHz and 70 MHz are observed for concentrations as low as 10 ng/ml, 20 ng/ml and 30 ng/ml of biotin-streptavidin respectively. Simulation results suggest that proposed biosensor is sensitive even for concentration of 5 ng/ml of sample.
射频交叉电容腔检测生物素-链霉亲和素相互作用
本文利用所设计的传感器在微波频率下检测生物素与链亲和素的相互作用。它利用两极滤波器拓扑结构,其中交错电容(IDC)用作谐振器之间的耦合区,以获得更高的灵敏度。由于生物素链霉亲和素组合的介电常数变化,共振频率发生移位,而由于电导率的变化,反射系数的大小发生变化。频率范围为10 GHz - 25 GHz (γ-色散区),因为它对生物素链亲和素的无标签分析有效。由于IDC指间电场均匀,生物素-链霉亲和素的放置位置不会影响灵敏度。当生物素-链亲和素的浓度分别低至10 ng/ml、20 ng/ml和30 ng/ml时,观察到高达19 MHz、45 MHz和70 MHz的显著频移。仿真结果表明,该传感器即使对5 ng/ml的样品浓度也很敏感。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信