{"title":"2D Heat Distribution Mapping of Monocrystalline Type Photovoltaic Placed in Universitas Budi Luhur Jakarta","authors":"Eka Purwa Laksana, Yani Prabowo, Sujono, Rummi Sirait, Nifty Fath, A. Priyadi, V. Lystianingrum, M. Purnomo, I. Riyanto","doi":"10.1109/ISRITI48646.2019.9034639","DOIUrl":null,"url":null,"abstract":"Due to exposure to direct sunlight, rooftop PV panels often suffers from heating. Performance of monocrystalline photovoltaic (MCPV) cell/panel is affected by its thermal properties, therefore, this research aims to measure the performance of MCPV through 2-dimensional heat mapping to determine the most efficient cooling scheme for the PV to maintain its most optimum performance. The measurement, mapping, and calculation is conducted on an array of experimental rooftop PV panel installed on a building, heat mapping data is taken from 55 points on PV surface. Measurement result shows that the high temperature of the MCPV panel is around 58,6oC - 64,7oC. Based on the results, the recommendation of temperature sensor placement for the cooling process is located at point 23 and 47.","PeriodicalId":367363,"journal":{"name":"2019 International Seminar on Research of Information Technology and Intelligent Systems (ISRITI)","volume":"2011 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Seminar on Research of Information Technology and Intelligent Systems (ISRITI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISRITI48646.2019.9034639","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Due to exposure to direct sunlight, rooftop PV panels often suffers from heating. Performance of monocrystalline photovoltaic (MCPV) cell/panel is affected by its thermal properties, therefore, this research aims to measure the performance of MCPV through 2-dimensional heat mapping to determine the most efficient cooling scheme for the PV to maintain its most optimum performance. The measurement, mapping, and calculation is conducted on an array of experimental rooftop PV panel installed on a building, heat mapping data is taken from 55 points on PV surface. Measurement result shows that the high temperature of the MCPV panel is around 58,6oC - 64,7oC. Based on the results, the recommendation of temperature sensor placement for the cooling process is located at point 23 and 47.
雅加达Budi Luhur大学单晶型光伏的二维热分布图
由于暴露在阳光直射下,屋顶光伏板经常受到加热的影响。单晶光伏(MCPV)电池/面板的性能受到其热性能的影响,因此,本研究旨在通过二维热成像来测量MCPV的性能,以确定最有效的冷却方案,使PV保持其最佳性能。对安装在建筑物上的一组实验性屋顶光伏板进行测量、测绘和计算,热图数据取自光伏表面的55个点。测量结果表明,MCPV面板的高温在58.6℃~ 64.7℃之间。根据结果,建议冷却过程的温度传感器位置位于点23和47。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信