{"title":"Active common-mode voltage reduction in a fault-tolerant three-phase inverter","authors":"D. Mohammadi, S. Ahmed-Zaid","doi":"10.1109/APEC.2016.7468264","DOIUrl":null,"url":null,"abstract":"A fault-tolerant topology in a three-phase four-leg inverter which is capable of reducing the common-mode voltage (CMV) during the post-fault condition is presented. The CMV during both post-fault and pre-fault is investigated. This paper proposes a topology to reduce the common-mode voltage during pre- and post-fault operation of the inverter by using the healthy switches. The accompanying simulation results verify the common-mode current reduction during the fault period.","PeriodicalId":143091,"journal":{"name":"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2016.7468264","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A fault-tolerant topology in a three-phase four-leg inverter which is capable of reducing the common-mode voltage (CMV) during the post-fault condition is presented. The CMV during both post-fault and pre-fault is investigated. This paper proposes a topology to reduce the common-mode voltage during pre- and post-fault operation of the inverter by using the healthy switches. The accompanying simulation results verify the common-mode current reduction during the fault period.
容错三相逆变器的有源共模电压降低
提出了一种能够降低故障后共模电压的三相四脚逆变器容错拓扑结构。研究了故障后和故障前的CMV。本文提出了一种利用健康开关降低逆变器故障前后共模电压的拓扑结构。仿真结果验证了故障期间共模电流减小的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信