Research on a Bioradar Based on the Analog Correlator

Hang Lan, Chunhong Chen, Chao Fang, Jiahao Chen, Yulan Lin
{"title":"Research on a Bioradar Based on the Analog Correlator","authors":"Hang Lan, Chunhong Chen, Chao Fang, Jiahao Chen, Yulan Lin","doi":"10.1109/IMBIOC.2019.8777923","DOIUrl":null,"url":null,"abstract":"This paper presents a 5.75 GHz high-resolution continuous wave Doppler bioradar system based on the analog correlator. It is used to detect the breathing and heartbeat signals of a stationary human body. To reduce the power consumption of the system, the quadrature demodulation receiver is replaced by the analog correlator to generate the quadrature baseband signal. A radio frequency leakage cancellation module based on the six-port network is used at the front end to improve the detection sensitivity and the Tx-Rx isolation. The results show that the bioradar can accurately measure the heartbeat and respiratory rates at a distance of 1.5 meters.","PeriodicalId":171472,"journal":{"name":"2019 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)","volume":"164 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMBIOC.2019.8777923","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents a 5.75 GHz high-resolution continuous wave Doppler bioradar system based on the analog correlator. It is used to detect the breathing and heartbeat signals of a stationary human body. To reduce the power consumption of the system, the quadrature demodulation receiver is replaced by the analog correlator to generate the quadrature baseband signal. A radio frequency leakage cancellation module based on the six-port network is used at the front end to improve the detection sensitivity and the Tx-Rx isolation. The results show that the bioradar can accurately measure the heartbeat and respiratory rates at a distance of 1.5 meters.
基于模拟相关器的生物雷达研究
提出了一种基于模拟相关器的5.75 GHz高分辨率连续波多普勒生物雷达系统。它被用来检测静止人体的呼吸和心跳信号。为了降低系统功耗,用模拟相关器代替正交解调接收机产生正交基带信号。前端采用基于六口网络的射频泄漏抵消模块,提高检测灵敏度和Tx-Rx隔离度。结果表明,该生物雷达可以在1.5米距离内准确测量心跳和呼吸频率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信