Modularized bi-directional grid-tied inverter with asynchronous sigma-delta modulation

Yaow-Ming Chen, Chia-Hsi Chang
{"title":"Modularized bi-directional grid-tied inverter with asynchronous sigma-delta modulation","authors":"Yaow-Ming Chen, Chia-Hsi Chang","doi":"10.1109/ECCE.2010.5618153","DOIUrl":null,"url":null,"abstract":"The objective of this paper is to propose a modularized bi-directional grid-tied inverter (BGI) with asynchronous sigma-delta modulation (ASDM) control for the renewable energy (RE)-supplied DC power system. The proposed BGI can be operated either in the grid-tied mode (GTM) or the power factor correction mode (PFCM) which is necessary features for the RE-supplied DC power system. The proposed BGI with ASDM control scheme has the merits of circuit simplicity, quick response, and low electromagnetic interference. Moreover, the proposed BGI has redundant central controller which can increase the system reliability. The major contribution of this paper includes that developing the modularized BGI with ASDM control scheme for GTM and PFCM operations thoroughly and applying it to the RE-supplied DC power system successfully. In this paper, the mathematical equations of the proposed BGI with ASDM will be derived. Computer simulations and hardware experiments are shown to verify the performance of the proposed modularized BGI with ASDM control.","PeriodicalId":161915,"journal":{"name":"2010 IEEE Energy Conversion Congress and Exposition","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE Energy Conversion Congress and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2010.5618153","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The objective of this paper is to propose a modularized bi-directional grid-tied inverter (BGI) with asynchronous sigma-delta modulation (ASDM) control for the renewable energy (RE)-supplied DC power system. The proposed BGI can be operated either in the grid-tied mode (GTM) or the power factor correction mode (PFCM) which is necessary features for the RE-supplied DC power system. The proposed BGI with ASDM control scheme has the merits of circuit simplicity, quick response, and low electromagnetic interference. Moreover, the proposed BGI has redundant central controller which can increase the system reliability. The major contribution of this paper includes that developing the modularized BGI with ASDM control scheme for GTM and PFCM operations thoroughly and applying it to the RE-supplied DC power system successfully. In this paper, the mathematical equations of the proposed BGI with ASDM will be derived. Computer simulations and hardware experiments are shown to verify the performance of the proposed modularized BGI with ASDM control.
模块化双向并网异步调制逆变器
本文的目标是为可再生能源(RE)供电的直流电力系统提出一种具有异步σ - δ调制(ASDM)控制的模块化双向并网逆变器(BGI)。提出的BGI可以在并网模式(GTM)或功率因数校正模式(PFCM)下运行,这是re供电的直流电源系统的必要特征。所提出的ASDM控制方案具有电路简单、响应速度快、电磁干扰小等优点。此外,该系统具有冗余的中央控制器,提高了系统的可靠性。本文的主要贡献在于,对GTM和PFCM运行进行了全面的模块化ASDM控制方案的开发,并成功地将其应用于re供电的直流电源系统。本文将推导出具有ASDM的BGI的数学方程。计算机仿真和硬件实验验证了采用ASDM控制的模块化BGI的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信