Mechanical Complications of Posterior Implant Restorations using CAD/CAM Titanium Customized Abutments: A Retrospective Study

Minyoung Yang, Jae-Seung Chang, Woo Ji, Sunjai Kim
{"title":"Mechanical Complications of Posterior Implant Restorations using CAD/CAM Titanium Customized Abutments: A Retrospective Study","authors":"Minyoung Yang, Jae-Seung Chang, Woo Ji, Sunjai Kim","doi":"10.32542/implantology.2019012","DOIUrl":null,"url":null,"abstract":"Copyright © 2019. The Korean Academy of Oral & Maxillofacial Implantology This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons. org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. OPEN ACCESS Purpose: The purpose of this retrospective study was to evaluate the incidence of mechanical complications of the posterior implant-supported fixed dental prosthesis (p-ISFDP) using computeraided design and computer-aided manufacturing (CAD/CAM) titanium customized abutments and to evaluate the influencing factors on complications. Material and Methods: The incidence and consequences of mechanical complications in p-ISFDPs over a mean follow up period of 54.43 ± 6.24 months were assessed based on electronic documentations f rom 138 patients with 266 implants. All p-ISFDP utilized CAD/CAM titanium customized abutments, and were fabricated with cement-retained prostheses with occlusal screw access holes. Statistical analyses were performed to identify the risk factors of mechanical complications. Results: During the observation period (3 5 years), implant survival rates were 100%. Major mechanical complications were 8 abutment f ractures (3.01%), 8 screw loosenings (3.01%), 2 screw fractures (0.75%), 11 chipping or fractures of veneering materials (5.58%), 23 decementations of the superstructure (11.68%). The relationship between the incidence of mechanical complications and the possible factors were not statistically significant(p > .05). Conclusion: There is no significant difference between each mechanical complication and the risk factors. P-ISFDP fabricated with CAD/CAM titanium abutments is a clinically acceptable treatment.","PeriodicalId":370954,"journal":{"name":"The Korean Academy of Oral and Maxillofacial Implantology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Korean Academy of Oral and Maxillofacial Implantology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32542/implantology.2019012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Copyright © 2019. The Korean Academy of Oral & Maxillofacial Implantology This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons. org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. OPEN ACCESS Purpose: The purpose of this retrospective study was to evaluate the incidence of mechanical complications of the posterior implant-supported fixed dental prosthesis (p-ISFDP) using computeraided design and computer-aided manufacturing (CAD/CAM) titanium customized abutments and to evaluate the influencing factors on complications. Material and Methods: The incidence and consequences of mechanical complications in p-ISFDPs over a mean follow up period of 54.43 ± 6.24 months were assessed based on electronic documentations f rom 138 patients with 266 implants. All p-ISFDP utilized CAD/CAM titanium customized abutments, and were fabricated with cement-retained prostheses with occlusal screw access holes. Statistical analyses were performed to identify the risk factors of mechanical complications. Results: During the observation period (3 5 years), implant survival rates were 100%. Major mechanical complications were 8 abutment f ractures (3.01%), 8 screw loosenings (3.01%), 2 screw fractures (0.75%), 11 chipping or fractures of veneering materials (5.58%), 23 decementations of the superstructure (11.68%). The relationship between the incidence of mechanical complications and the possible factors were not statistically significant(p > .05). Conclusion: There is no significant difference between each mechanical complication and the risk factors. P-ISFDP fabricated with CAD/CAM titanium abutments is a clinically acceptable treatment.
使用CAD/CAM定制钛基牙修复后种植体的机械并发症:回顾性研究
版权所有©2019。韩国口腔颌面种植学会这是一篇基于知识共享署名非商业许可(http://creativecommons)的开放获取文章。(http://www.licenses/bync/4.0/),允许在任何媒介上不受限制地进行非商业使用、分发和复制,前提是正确引用原始作品。目的:回顾性研究计算机辅助设计和计算机辅助制造(CAD/CAM)钛定制基牙后牙种植固定义齿(p-ISFDP)机械并发症的发生率,并评价并发症的影响因素。材料与方法:在平均54.43±6.24个月的随访期间,根据来自138例患者的266个假体的电子文档,评估p- isfdp机械并发症的发生率和后果。所有p-ISFDP均使用CAD/CAM定制钛基台,并使用带咬合螺钉接入孔的水泥保留假体制作。统计学分析确定机械并发症的危险因素。结果:观察期内(35年)种植体成活率为100%。主要机械并发症为基牙断裂8例(3.01%),螺钉松动8例(3.01%),螺钉断裂2例(0.75%),贴面材料碎裂或断裂11例(5.58%),上部结构变形23例(11.68%)。机械并发症发生率与可能因素的关系无统计学意义(p < 0.05)。结论:各机械并发症及危险因素无显著性差异。用CAD/CAM钛基台制造P-ISFDP是一种临床可接受的治疗方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信