{"title":"Modeling and performance analysis of special permanent magnetic excitation six-phase synchronous generators for wind farm application","authors":"F. H. da Costa, Rafael Nakamura, J. C. Oliveira, G. C. Guimarães, A. F. Bonelli","doi":"10.1109/EPQU.2011.6128833","DOIUrl":null,"url":null,"abstract":"This paper presents a proposal for the mathematical modeling and computational analysis of special permanent magnetic excitation six-phase synchronous generators, as required by variable wind farm application. The strategy uses time domain techniques so as to highlight the transient, dynamic and steady state operational conditions. Having completed the representation and the computational implementation of these special machines, the representation is implemented in the ATP platform and performance analyses are carried out to highlight the main operational characteristics of the special generator.","PeriodicalId":369941,"journal":{"name":"11th International Conference on Electrical Power Quality and Utilisation","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"11th International Conference on Electrical Power Quality and Utilisation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPQU.2011.6128833","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
This paper presents a proposal for the mathematical modeling and computational analysis of special permanent magnetic excitation six-phase synchronous generators, as required by variable wind farm application. The strategy uses time domain techniques so as to highlight the transient, dynamic and steady state operational conditions. Having completed the representation and the computational implementation of these special machines, the representation is implemented in the ATP platform and performance analyses are carried out to highlight the main operational characteristics of the special generator.