{"title":"[Experience with the AGC-2000 type bicondylar surface-substituting knee prosthesis].","authors":"L Hangody,&nbsp;L Sükösd,&nbsp;A Gábor,&nbsp;Z Kárpáti","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Authors report on the first use of bicondylar surface substitution knee prosthesis of a new type. The prosthesis and the instruments developed for implantation are demonstrated. In the first five operations the appropriateness of the implantation instruments, the exactness of their handling, the assortment of the series of prosthesis have met the plus which, compared to the types known until now, can secure the exactness of the operation and improve the ratio of the lasting good results.</p>","PeriodicalId":74098,"journal":{"name":"Magyar traumatologia, orthopaedia es helyreallito sebeszet","volume":"35 2","pages":"137-40"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magyar traumatologia, orthopaedia es helyreallito sebeszet","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Authors report on the first use of bicondylar surface substitution knee prosthesis of a new type. The prosthesis and the instruments developed for implantation are demonstrated. In the first five operations the appropriateness of the implantation instruments, the exactness of their handling, the assortment of the series of prosthesis have met the plus which, compared to the types known until now, can secure the exactness of the operation and improve the ratio of the lasting good results.

AGC-2000型双髁表面置换膝关节假体的应用经验
作者报告了一种新型双髁表面置换膝关节假体的首次应用。展示了为植入而开发的假体和器械。在前五次手术中,植入器械的适宜性、操作的准确性、假体系列的配合比均达到了目前已知的标准,保证了手术的准确性,提高了术后持久良好的成功率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信