Cavity methods of investigation of gas and condensed medium in MM AND SubMM ranges

V. Parshin, E. Serov
{"title":"Cavity methods of investigation of gas and condensed medium in MM AND SubMM ranges","authors":"V. Parshin, E. Serov","doi":"10.1109/CRMICO.2010.5632432","DOIUrl":null,"url":null,"abstract":"For MM and SubMM ranges, on the basis of high-quality Fabry-Perot resonator the original precision methods of investigation are discussed: atmospheric absorption, including continuum absorption; radiant reflectance of metals; refraction index and loss tangent of dielectrics, including films and liquids. The methods of measurement are absolute ones and self“calibrated” that means it is not necessary to use the prior information. Concrete values are calculated on the basis of measuring of adjustment frequency and line width of empty and loaded resonator. The temperature range is 80 K-900 K for investigation of condensed medium; for atmospheric - from -30 C up to +60 C and at humidity - 0%-80%. The measurement results of latest polymeric materials are presented.","PeriodicalId":237662,"journal":{"name":"2010 20th International Crimean Conference \"Microwave & Telecommunication Technology\"","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 20th International Crimean Conference \"Microwave & Telecommunication Technology\"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CRMICO.2010.5632432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

For MM and SubMM ranges, on the basis of high-quality Fabry-Perot resonator the original precision methods of investigation are discussed: atmospheric absorption, including continuum absorption; radiant reflectance of metals; refraction index and loss tangent of dielectrics, including films and liquids. The methods of measurement are absolute ones and self“calibrated” that means it is not necessary to use the prior information. Concrete values are calculated on the basis of measuring of adjustment frequency and line width of empty and loaded resonator. The temperature range is 80 K-900 K for investigation of condensed medium; for atmospheric - from -30 C up to +60 C and at humidity - 0%-80%. The measurement results of latest polymeric materials are presented.
MM和SubMM范围内气体和冷凝介质的空腔研究方法
对于MM和SubMM范围,在高质量法布里-珀罗谐振器的基础上,讨论了原有的精度研究方法:大气吸收,包括连续介质吸收;金属的辐射反射率;介质的折射率和损耗正切,包括薄膜和液体。测量方法是绝对的和自我“校准”的,这意味着不需要使用先验信息。通过测量空腔和负载腔的调整频率和线宽,计算出具体数值。研究冷凝介质的温度范围为80 ~ 900 K;适用于-30℃至+60℃的大气环境,湿度为- 0%-80%。介绍了最新高分子材料的测试结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信