Overvoltages and power oscillations in hydro generators

Z. Maljkovic, I. Gašparac, M. Miroševic
{"title":"Overvoltages and power oscillations in hydro generators","authors":"Z. Maljkovic, I. Gašparac, M. Miroševic","doi":"10.1109/ICCEP.2015.7177547","DOIUrl":null,"url":null,"abstract":"The paper describes two specific transient phenomena of different characteristic frequencies. First, a short overview of a calculation of overvoltages in the generator main electrical circuit of a hydro power station is presented. A case of a generator connected to the step-up transformer through encapsulated lines has been studied. The most critical cases have been considered: overvoltages at a single phase earth fault in the generator circuit and temporary overvoltages due to the single phase earth fault followed by the load rejection. The calculations have been carried out by EMTP-ATP and MicroTran program. Second, electric power oscillations in hydro power plants are not rare. The paper shows two cases in two different power plants. Each power plant has different generator positions (one vertical and one horizontal bulb type) and therefore different reasons for power oscillations. An overview of those cases is presented supported by measurements and calculated by Matlab.","PeriodicalId":423870,"journal":{"name":"2015 International Conference on Clean Electrical Power (ICCEP)","volume":"160 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Clean Electrical Power (ICCEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCEP.2015.7177547","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The paper describes two specific transient phenomena of different characteristic frequencies. First, a short overview of a calculation of overvoltages in the generator main electrical circuit of a hydro power station is presented. A case of a generator connected to the step-up transformer through encapsulated lines has been studied. The most critical cases have been considered: overvoltages at a single phase earth fault in the generator circuit and temporary overvoltages due to the single phase earth fault followed by the load rejection. The calculations have been carried out by EMTP-ATP and MicroTran program. Second, electric power oscillations in hydro power plants are not rare. The paper shows two cases in two different power plants. Each power plant has different generator positions (one vertical and one horizontal bulb type) and therefore different reasons for power oscillations. An overview of those cases is presented supported by measurements and calculated by Matlab.
水轮发电机的过电压和功率振荡
本文描述了两种不同特征频率的瞬态现象。首先,简要介绍了水电站发电机主电路过电压的计算方法。研究了发电机通过封装线路与升压变压器连接的情况。考虑了最关键的情况:发电机电路中单相接地故障引起的过电压和单相接地故障引起的暂时过电压,然后是负载丢弃。用EMTP-ATP和MicroTran程序进行了计算。其次,水力发电厂的电力振荡并不罕见。本文展示了两个不同电厂的两个案例。每个发电厂有不同的发电机位置(一个垂直和一个水平灯泡类型),因此功率振荡的原因不同。通过测量和Matlab计算,对这些情况进行了概述。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信