Bruno Santos, T. Leao, E. Drigo, J. Fonseca, A. Andrade, Breno Nishida, E. Bock
{"title":"Design of a Hydrodynamic Performance Bench for Ventricular Assist Devices","authors":"Bruno Santos, T. Leao, E. Drigo, J. Fonseca, A. Andrade, Breno Nishida, E. Bock","doi":"10.32640/tasj.2022.1.7","DOIUrl":null,"url":null,"abstract":"This work presents the design of a hydrodynamic performance bench (HPB) of Ventricular Assist Devices (VADs) for evaluations of developed prototypes. VADs are used for the treatment of patients with Congestive Heart Failure (CHF), either as a bridge to recovery, for transplantation or as destination therapy. HPB is required for the performance evaluation of VADs that are under development in Brazil. The performance evaluation of a VAD considers the rotation speed [rpm], flow rate [L/min], pressure [mmHg] and power [W]. The project consists in choosing an actuator and transducers from HPB, and developing the mechanical components, supervisory control and modules. The HPB mechanical components were designed in SolidWorks® following rapid prototyping and built by additive manufacturing. The HPB supervisory program was developed in graphic language through the Labview® program and implemented in a development and application platform with data acquisition system. The manipulated variable of the supervisory system is the motor speed [rpm] acting via an Escon 50/4 EC-S power controller on the BLDC EC45 N339281 motor. The controlled variable is the “VAD flow” [L/min] provided by an HT-110 flow transducer. A particle image velocimetry (PIV) module was developed for flow analysis. All process data are stored in spreadsheets for later consultation. HPB could assist in a satisfactory way in the analysis of the developed VADs prototypes, demonstrating the technical success of the project.","PeriodicalId":227717,"journal":{"name":"The Academic Society Journal","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Academic Society Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32640/tasj.2022.1.7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
This work presents the design of a hydrodynamic performance bench (HPB) of Ventricular Assist Devices (VADs) for evaluations of developed prototypes. VADs are used for the treatment of patients with Congestive Heart Failure (CHF), either as a bridge to recovery, for transplantation or as destination therapy. HPB is required for the performance evaluation of VADs that are under development in Brazil. The performance evaluation of a VAD considers the rotation speed [rpm], flow rate [L/min], pressure [mmHg] and power [W]. The project consists in choosing an actuator and transducers from HPB, and developing the mechanical components, supervisory control and modules. The HPB mechanical components were designed in SolidWorks® following rapid prototyping and built by additive manufacturing. The HPB supervisory program was developed in graphic language through the Labview® program and implemented in a development and application platform with data acquisition system. The manipulated variable of the supervisory system is the motor speed [rpm] acting via an Escon 50/4 EC-S power controller on the BLDC EC45 N339281 motor. The controlled variable is the “VAD flow” [L/min] provided by an HT-110 flow transducer. A particle image velocimetry (PIV) module was developed for flow analysis. All process data are stored in spreadsheets for later consultation. HPB could assist in a satisfactory way in the analysis of the developed VADs prototypes, demonstrating the technical success of the project.