A Practical Approach to Eliminating DC Magnetic Flux from the Series Transformer of a Dynamic Voltage Restorer

T. Jimichi, H. Fujita, H. Akagi
{"title":"A Practical Approach to Eliminating DC Magnetic Flux from the Series Transformer of a Dynamic Voltage Restorer","authors":"T. Jimichi, H. Fujita, H. Akagi","doi":"10.1109/PCCON.2007.373187","DOIUrl":null,"url":null,"abstract":"This paper proposes a control method for eliminating dc magnetic flux from the series transformer of a DVR. The method is characterized by intentionally injecting no compensating voltage during a one-sixth line cycle (=3.3 ms at 50 Hz). The control sequence is independent of an initial phase angle of a voltage sag, thus requiring no flux detection. The period, during which no compensating voltage is injected, is one-third as short as that of an existing method. This paper verifies the effectiveness and viability of the proposed method, using a 200-V, 5-kW laboratory system. The proposed method brings no dc magnetic flux to the series transformer.","PeriodicalId":325362,"journal":{"name":"2007 Power Conversion Conference - Nagoya","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Power Conversion Conference - Nagoya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCCON.2007.373187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper proposes a control method for eliminating dc magnetic flux from the series transformer of a DVR. The method is characterized by intentionally injecting no compensating voltage during a one-sixth line cycle (=3.3 ms at 50 Hz). The control sequence is independent of an initial phase angle of a voltage sag, thus requiring no flux detection. The period, during which no compensating voltage is injected, is one-third as short as that of an existing method. This paper verifies the effectiveness and viability of the proposed method, using a 200-V, 5-kW laboratory system. The proposed method brings no dc magnetic flux to the series transformer.
一种消除动态电压恢复器串联变压器直流磁通的实用方法
提出了一种消除DVR串联变压器直流磁通的控制方法。该方法的特点是在六分之一的线路周期(=3.3 ms, 50 Hz)内故意注入不补偿电压。控制序列与电压暂降的初始相位角无关,因此不需要磁链检测。在此期间不注入补偿电压,比现有方法短三分之一。本文利用一个200v, 5kw的实验室系统验证了该方法的有效性和可行性。该方法对串联变压器无直流磁通。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信