{"title":"Study on Monitoring of Measurement of Radiation Doses in Paediatric Age Group in NICU and PICU","authors":"Arvind K. Takle, Nitin B. Gorde","doi":"10.9734/bpi/nfmmr/v7/3314f","DOIUrl":null,"url":null,"abstract":"The radiation doses received by different age groups in the NICU and PICU, as well as in the general population, are investigated. This research was carried out in strict accordance with the AERB's radiation guidelines and international radiation safety regulations. Dedicated X-Ray Unit, Careful collimation, minimum / optimum radiation factors, appropriate FFD, 1.5 mm Aluminum filter, C.R. cassettes, verified and calibrated X-Ray Machine, calibrated X-Ray dosimeter, were taken care of. The study has been made of X-Ray examination of Pediatric patients in the B.V.D.U. Medical College and Hospital, Sangli, to provide information on pediatric dose levels. The radiation survey is made to check the radiation exposure received by the patient in multiple exposure is under the safer limit laid by the international and by Indian Radiation Authority. Critical image quality of Radiographs was evaluated by Pediatric and departmental Radiologists. The result shows a linear relationship between the dose received and age of the patient. Chest X-Ray examination for Pediatric Chest X-Ray study was studied in NICU, PICU to assess the radiation dose received and conclusion were made. ESD was calculated from quality control measurements on the X- Ray unit itself. Direct measurements of radiation doses also measured using, highly sensitive, calibrated, tested for consistency in sensitivity, dosimeter.","PeriodicalId":231604,"journal":{"name":"New Frontiers in Medicine and Medical Research Vol. 7","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"New Frontiers in Medicine and Medical Research Vol. 7","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/bpi/nfmmr/v7/3314f","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The radiation doses received by different age groups in the NICU and PICU, as well as in the general population, are investigated. This research was carried out in strict accordance with the AERB's radiation guidelines and international radiation safety regulations. Dedicated X-Ray Unit, Careful collimation, minimum / optimum radiation factors, appropriate FFD, 1.5 mm Aluminum filter, C.R. cassettes, verified and calibrated X-Ray Machine, calibrated X-Ray dosimeter, were taken care of. The study has been made of X-Ray examination of Pediatric patients in the B.V.D.U. Medical College and Hospital, Sangli, to provide information on pediatric dose levels. The radiation survey is made to check the radiation exposure received by the patient in multiple exposure is under the safer limit laid by the international and by Indian Radiation Authority. Critical image quality of Radiographs was evaluated by Pediatric and departmental Radiologists. The result shows a linear relationship between the dose received and age of the patient. Chest X-Ray examination for Pediatric Chest X-Ray study was studied in NICU, PICU to assess the radiation dose received and conclusion were made. ESD was calculated from quality control measurements on the X- Ray unit itself. Direct measurements of radiation doses also measured using, highly sensitive, calibrated, tested for consistency in sensitivity, dosimeter.
NICU和PICU儿科年龄组辐射剂量监测的研究
调查了NICU和PICU中不同年龄组以及一般人群所接受的辐射剂量。这项研究严格按照AERB的辐射准则和国际辐射安全条例进行。专门的x射线单元,仔细的准直,最小/最佳辐射因子,适当的FFD, 1.5 mm铝滤光片,C.R.卡带,验证和校准的x射线机,校准的x射线剂量计。这项研究对桑丽B.V.D.U.医学院和医院的儿科患者进行了x射线检查,以提供有关儿科剂量水平的信息。进行辐射调查是为了检查病人在多次照射下所受的辐射是否在国际和印度辐射管理局规定的安全限度之内。放射科医师和儿科放射科医师对x光片的关键图像质量进行了评估。结果显示,接受的剂量与病人的年龄呈线性关系。对新生儿重症监护病房(NICU)、重症监护病房(PICU)的儿童胸部x线检查进行评估,得出结论。静电放电是从X射线装置本身的质量控制测量中计算出来的。辐射剂量的直接测量也使用高灵敏度、校准、测试灵敏度一致性的剂量计进行测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信