Analysis of Influence of the Design of the Discharge Chamber on the Ozone Generator Parameters

Y. Sokol, V. Kulichenko, R. Tomashevskyi, M. Makhonin
{"title":"Analysis of Influence of the Design of the Discharge Chamber on the Ozone Generator Parameters","authors":"Y. Sokol, V. Kulichenko, R. Tomashevskyi, M. Makhonin","doi":"10.1109/ELNANO.2018.8477441","DOIUrl":null,"url":null,"abstract":"The influence of design parameters of a discharge chamber of an ozone generator on its output characteristics is described in the article. Ways of obtaining ozone and its use in medical practice are given. The problems of determining the discharge voltage, electrical parameters of the coaxial and flat types of chambers are considered. Mathematical description of the determination of the value of ozone concentration in the discharge chamber of the generator is given. A model that takes into account the influence of the design parameters of the discharge chamber is proposed. Its investigation and comparison with the experimental data obtained on the model of the ozone generator are carried out. Its adequacy has been confirmed.","PeriodicalId":269665,"journal":{"name":"2018 IEEE 38th International Conference on Electronics and Nanotechnology (ELNANO)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 38th International Conference on Electronics and Nanotechnology (ELNANO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELNANO.2018.8477441","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The influence of design parameters of a discharge chamber of an ozone generator on its output characteristics is described in the article. Ways of obtaining ozone and its use in medical practice are given. The problems of determining the discharge voltage, electrical parameters of the coaxial and flat types of chambers are considered. Mathematical description of the determination of the value of ozone concentration in the discharge chamber of the generator is given. A model that takes into account the influence of the design parameters of the discharge chamber is proposed. Its investigation and comparison with the experimental data obtained on the model of the ozone generator are carried out. Its adequacy has been confirmed.
放电室设计对臭氧发生器参数的影响分析
介绍了臭氧发生器放电室设计参数对其输出特性的影响。介绍了臭氧的获取方法及其在医疗实践中的应用。考虑了同轴腔和平板腔放电电压、电学参数的确定问题。给出了发生器放电室臭氧浓度数值测定的数学描述。提出了考虑放电室设计参数影响的模型。对其进行了研究,并与臭氧发生器模型的实验数据进行了比较。其充分性已得到证实。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信