{"title":"A simple pre-stress estimating method of langevin transducers","authors":"B. Fu, Tinglong Li, T. Hemsel","doi":"10.1109/SPAWDA.2008.4775801","DOIUrl":null,"url":null,"abstract":"A simple pre-stress estimate method of Langevin transducers is studied. The measurement setup consists of a capacitor, an impedance converter and a voltmeter. Based on the piezoelectric equation and the basic circuit theory, the mathematical expression between the pre-stress and the voltage across the capacitor is derived. The pre-stress level can then be calculated out of the measurement of the capacitor voltage. In order to evaluate the precision of this method, a force washer is used to measure the pre-stress of the Langevin transducer. The result shows the pre-stress level obtained from this method is 30-40% higher than the pre-stress level measured by the force washer. This method is simple and can be used to estimate the pre-stress of various Langevin transducers. The precision of this method can be raised if d33 is identified under different pre-stress levels.","PeriodicalId":190941,"journal":{"name":"2008 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPAWDA.2008.4775801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
A simple pre-stress estimate method of Langevin transducers is studied. The measurement setup consists of a capacitor, an impedance converter and a voltmeter. Based on the piezoelectric equation and the basic circuit theory, the mathematical expression between the pre-stress and the voltage across the capacitor is derived. The pre-stress level can then be calculated out of the measurement of the capacitor voltage. In order to evaluate the precision of this method, a force washer is used to measure the pre-stress of the Langevin transducer. The result shows the pre-stress level obtained from this method is 30-40% higher than the pre-stress level measured by the force washer. This method is simple and can be used to estimate the pre-stress of various Langevin transducers. The precision of this method can be raised if d33 is identified under different pre-stress levels.