Ex Vivo accuracy of an endodontic motor with an integrated apex locator in multirooted teeth: Research article

Alex Lvovsky, Gabriel Batashvili, S. Staffoli, Barbara G. Nunez Torrijos, G. Gambarini, M. Solomonov, J. B. Itzhak
{"title":"Ex Vivo accuracy of an endodontic motor with an integrated apex locator in multirooted teeth: Research article","authors":"Alex Lvovsky, Gabriel Batashvili, S. Staffoli, Barbara G. Nunez Torrijos, G. Gambarini, M. Solomonov, J. B. Itzhak","doi":"10.15761/OHC.1000190","DOIUrl":null,"url":null,"abstract":"Background: Endodontic motors with an integrated electronic apex locator have been tested for its accuracy mostly on single-rooted teeth. Multirooted teeth may create interferences on the readings created by the irrigation solution in the pulp chamber and additional canals. This study aimed to examine in vitro the accuracy of an integrated endodontic motor with an EAL attached in multirooted teeth. Methods: Extracted teeth on a model specially developed to test EALs were tested. The actual working length (WL) was measured with a 5x microscope and K-Files, EAL working length was measured with the pulp chamber flooded with sodium hypochlorite and the measure obtained shaping root canals with the auto apical reverse (AAR) mode, (an endodontic motor that attached to an EAL starts auto-reverse mode when the working length defined","PeriodicalId":217575,"journal":{"name":"Oral Health and Care","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral Health and Care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15761/OHC.1000190","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Endodontic motors with an integrated electronic apex locator have been tested for its accuracy mostly on single-rooted teeth. Multirooted teeth may create interferences on the readings created by the irrigation solution in the pulp chamber and additional canals. This study aimed to examine in vitro the accuracy of an integrated endodontic motor with an EAL attached in multirooted teeth. Methods: Extracted teeth on a model specially developed to test EALs were tested. The actual working length (WL) was measured with a 5x microscope and K-Files, EAL working length was measured with the pulp chamber flooded with sodium hypochlorite and the measure obtained shaping root canals with the auto apical reverse (AAR) mode, (an endodontic motor that attached to an EAL starts auto-reverse mode when the working length defined
集成牙尖定位器的多根牙髓马达离体精度研究
背景:带集成电子顶点定位器的牙髓马达在单根牙上的准确性已经得到了验证。多根牙可能会对牙髓室和其他根管中的冲洗液产生的读数产生干扰。本研究的目的是在体外测试一个集成的牙髓马达与EAL附着在多根牙的准确性。方法:拔牙在专门研制的EALs模型上进行试验。用5倍显微镜和K-Files测量实际工作长度(WL),用次氯酸钠浸水牙髓室测量EAL工作长度,并采用自动根尖反转(AAR)模式塑形根管,当确定工作长度时,附着在EAL上的根管电机启动自动反转模式
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信