Effect of interpolation on electroanatomical mapping

M. Sanromán-Junquera, Raquel Díaz-Valencia, A. García-Alberola, J. Rojo-álvarez, I. Mora-Jiménez
{"title":"Effect of interpolation on electroanatomical mapping","authors":"M. Sanromán-Junquera, Raquel Díaz-Valencia, A. García-Alberola, J. Rojo-álvarez, I. Mora-Jiménez","doi":"10.1109/CIC.2015.7408661","DOIUrl":null,"url":null,"abstract":"Cardiac navigation systems (CNS) are often used in electrophysiological studies to create spatial-electrical maps supporting the arrhythmia mechanism identification. Sequentially recorded electrograms yield the bioelectrical information from features such as voltage and activation times in terms of their spatial location, which are subsequently interpolated for building the electroanatomical map (EAM) of the cardiac chamber. Our goal was to evaluate quantitatively the effect of interpolation in the EAM accuracy when reconstructed from a set of samples. Triangulated irregular networks (TIN), thin plate spline (TPS), and support vector machines (SVM) were assessed by using: (a) two detailed simulated time activation maps during flutter and sinus rhythm in both atria; (b) a set of real CNS maps, given by 13 activation time and 19 voltage maps, with 6 right atria (RA), 6 left atria (LA), 4 right ventricles (RV), and 16 left ventricles (LV). Interpolation methods were benchmarked using root mean squared error (RMSE), efficiency (EF), and Willmott distance (WD). On the one hand, EF and WD were similar for yielding a clearer cut-off point than RMSE for the number of required samples, which was about 100. Better EAM accuracy was obtained using TPS, followed by SVM and TIN, except for flutter in the RA, where early-meets-late was smoothed by SVM. On the other hand, EAM accuracy (in terms of the average WD) was slightly outperformed by RA than LA (0.57 vs 0.52), whereas RV and LV were similar (0.71 vs 0.71). In reference to the methods, similar average WD was given by the interpolation methods (TIN 0.64 ± 0.14; TPS 0.66 ± 0.15; SVM 0.65 ± 0.18). The EAM accuracy is dependent on the map nature and on the cardiac chamber.","PeriodicalId":414802,"journal":{"name":"2015 Computing in Cardiology Conference (CinC)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Computing in Cardiology Conference (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2015.7408661","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Cardiac navigation systems (CNS) are often used in electrophysiological studies to create spatial-electrical maps supporting the arrhythmia mechanism identification. Sequentially recorded electrograms yield the bioelectrical information from features such as voltage and activation times in terms of their spatial location, which are subsequently interpolated for building the electroanatomical map (EAM) of the cardiac chamber. Our goal was to evaluate quantitatively the effect of interpolation in the EAM accuracy when reconstructed from a set of samples. Triangulated irregular networks (TIN), thin plate spline (TPS), and support vector machines (SVM) were assessed by using: (a) two detailed simulated time activation maps during flutter and sinus rhythm in both atria; (b) a set of real CNS maps, given by 13 activation time and 19 voltage maps, with 6 right atria (RA), 6 left atria (LA), 4 right ventricles (RV), and 16 left ventricles (LV). Interpolation methods were benchmarked using root mean squared error (RMSE), efficiency (EF), and Willmott distance (WD). On the one hand, EF and WD were similar for yielding a clearer cut-off point than RMSE for the number of required samples, which was about 100. Better EAM accuracy was obtained using TPS, followed by SVM and TIN, except for flutter in the RA, where early-meets-late was smoothed by SVM. On the other hand, EAM accuracy (in terms of the average WD) was slightly outperformed by RA than LA (0.57 vs 0.52), whereas RV and LV were similar (0.71 vs 0.71). In reference to the methods, similar average WD was given by the interpolation methods (TIN 0.64 ± 0.14; TPS 0.66 ± 0.15; SVM 0.65 ± 0.18). The EAM accuracy is dependent on the map nature and on the cardiac chamber.
插值对电解剖成像的影响
心脏导航系统(CNS)常用于电生理研究,以创建支持心律失常机制识别的空间电图。按顺序记录的心电图从电压和激活时间等特征中产生生物电信息,这些信息随后被内插以构建心腔的电解剖图(EAM)。我们的目标是定量评估从一组样本重建时插值对EAM精度的影响。采用以下方法对不规则三角网(TIN)、薄板样条(TPS)和支持向量机(SVM)进行评估:(a)两个心房颤振和窦性心律期间的详细模拟时间激活图;(b)一组真实的中枢神经系统图,由13个激活时间图和19个电压图组成,其中右心房(RA) 6个,左心房(LA) 6个,右心室(RV) 4个,左心室(LV) 16个。采用均方根误差(RMSE)、效率(EF)和威尔莫特距离(WD)对插值方法进行基准测试。一方面,EF和WD的相似之处是,对于所需样本的数量,它们比RMSE给出了更清晰的分界点,RMSE约为100。除RA中的颤振被SVM平滑外,TPS获得了较好的EAM精度,其次是SVM和TIN。另一方面,RA的EAM准确性(就平均WD而言)略优于LA (0.57 vs 0.52),而RV和LV相似(0.71 vs 0.71)。在参考方法的基础上,插值方法得到的平均WD值相近(TIN = 0.64±0.14;TPS 0.66±0.15;支持向量机0.65±0.18)。EAM的准确性取决于图的性质和心腔。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信