Practical application of partial discharge testing of insulation systems with emphasis on medium voltage switch gear

T. J. O'Brien
{"title":"Practical application of partial discharge testing of insulation systems with emphasis on medium voltage switch gear","authors":"T. J. O'Brien","doi":"10.1109/PAPCON.1998.685514","DOIUrl":null,"url":null,"abstract":"Partial discharge measurements of insulation systems is a known indicator of the initial stages of insulation breakdown. Weak, damaged or aging insulation leading to breakdown almost always exhibit partial discharge caused by a voltage stress across that weakness prior to a complete breakdown. The partial discharge is a measurable event and through research, development and experience is a qualitative assessment of a impending total insulation breakdown.","PeriodicalId":360061,"journal":{"name":"Conference Record of 1998 Annual Pulp and Paper Industry Technical Conference (Cat. No.98CH36219)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of 1998 Annual Pulp and Paper Industry Technical Conference (Cat. No.98CH36219)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAPCON.1998.685514","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Partial discharge measurements of insulation systems is a known indicator of the initial stages of insulation breakdown. Weak, damaged or aging insulation leading to breakdown almost always exhibit partial discharge caused by a voltage stress across that weakness prior to a complete breakdown. The partial discharge is a measurable event and through research, development and experience is a qualitative assessment of a impending total insulation breakdown.
绝缘系统局部放电试验的实际应用,重点是中压开关设备
绝缘系统的局部放电测量是绝缘击穿初始阶段的已知指标。导致击穿的薄弱、损坏或老化的绝缘几乎总是在完全击穿之前由穿过该薄弱处的电压应力引起部分放电。局部放电是一个可测量的事件,通过研究、开发和经验,是对即将发生的完全绝缘击穿的定性评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信