Effect of Lateral Cyclic Loading on Screw Loosening in Morse Taper Implant-Straight Abutment Connection

E. Jalalian, A. Zarbakhsh, Sarvenaz Zare, Hamed Karimi Pour
{"title":"Effect of Lateral Cyclic Loading on Screw Loosening in Morse Taper Implant-Straight Abutment Connection","authors":"E. Jalalian, A. Zarbakhsh, Sarvenaz Zare, Hamed Karimi Pour","doi":"10.24018/ejdent.2022.3.2.177","DOIUrl":null,"url":null,"abstract":"Background: Screw loosening is a common problem that can lead to mechanical and biological failure of dental implants. This study aimed to assess the effect of lateral cyclic loading on screw loosening (detorque value) in Morse taper implant-straight abutment connection. \nMethods: This in vitro, experimental study evaluated 12 dental implants with Morse taper implant-abutment connection. Dental implant-abutment assemblies were mounted in transparent acrylic resin blocks with 45-degree angle relative to the acrylic surface. The abutment screw was torqued to 30 N/cm by a digital torque-meter and retorqued after 10 minutes. The assemblies were then randomly divided into two groups (n=6). In the test group, lateral cyclic loads with 75 N magnitude and 1 Hz frequency were applied at 45-degree angle relative to the longitudinal axis of the fixture. After 500,000 cycles, the detorque value was measured at the implant-abutment interface by a digital torque-meter. The assemblies in the control group did not undergo cyclic loading. The detorque values were compared between the two groups using the Student t-test (alpha=0.05). \nResults: The mean detorque value was 23.17±1.33 N/cm in the control and 21.3±3.38 N/cm in the test group. According to the Student t-test, this difference was not significant (P=0.4). \nConclusion: According to the present results, application of lateral cyclic loads had no significant effect on screw loosening (detorque value) of Morse taper implant-straight abutment connection but insignificantly increased the torque loss.","PeriodicalId":197045,"journal":{"name":"European Journal of Dental and Oral Health","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Dental and Oral Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24018/ejdent.2022.3.2.177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Screw loosening is a common problem that can lead to mechanical and biological failure of dental implants. This study aimed to assess the effect of lateral cyclic loading on screw loosening (detorque value) in Morse taper implant-straight abutment connection. Methods: This in vitro, experimental study evaluated 12 dental implants with Morse taper implant-abutment connection. Dental implant-abutment assemblies were mounted in transparent acrylic resin blocks with 45-degree angle relative to the acrylic surface. The abutment screw was torqued to 30 N/cm by a digital torque-meter and retorqued after 10 minutes. The assemblies were then randomly divided into two groups (n=6). In the test group, lateral cyclic loads with 75 N magnitude and 1 Hz frequency were applied at 45-degree angle relative to the longitudinal axis of the fixture. After 500,000 cycles, the detorque value was measured at the implant-abutment interface by a digital torque-meter. The assemblies in the control group did not undergo cyclic loading. The detorque values were compared between the two groups using the Student t-test (alpha=0.05). Results: The mean detorque value was 23.17±1.33 N/cm in the control and 21.3±3.38 N/cm in the test group. According to the Student t-test, this difference was not significant (P=0.4). Conclusion: According to the present results, application of lateral cyclic loads had no significant effect on screw loosening (detorque value) of Morse taper implant-straight abutment connection but insignificantly increased the torque loss.
横向循环荷载对莫氏锥度种植体-直基台连接螺钉松动的影响
背景:螺钉松动是一种常见的问题,可导致种植体的机械和生物失效。本研究旨在探讨横向循环载荷对莫尔斯锥度种植体-直基台连接螺钉松动(脱扭值)的影响。方法:对12种采用莫尔斯锥度种植体-基台连接的种植体进行体外实验研究。种植体-基台组件安装在透明丙烯酸树脂块中,与丙烯酸表面呈45度角。通过数字式扭矩计将基牙螺钉扭矩至30 N/cm, 10分钟后复位。然后将这些集合随机分为两组(n=6)。在试验组中,以相对于夹具纵轴45度角施加75 N量级和1 Hz频率的横向循环载荷。50万次循环后,用数字扭矩计在种植体-基牙界面处测量解扭矩值。对照组的组件不进行循环加载。采用学生t检验比较两组间的转矩值(alpha=0.05)。结果:对照组平均脱扭值为23.17±1.33 N/cm,试验组平均脱扭值为21.3±3.38 N/cm。根据学生t检验,这一差异不显著(P=0.4)。结论:根据本研究结果,施加横向循环载荷对Morse锥度种植体-直基台连接螺钉松动(解扭值)无显著影响,但扭矩损失不显著增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信