The effect of Applied-voltage on photon-number of corona discharge on transmission lines defect

S. Wan, Xuesong Zhao, Xinyang Guo, Chen Lan, X. Bian, Wenjun Yao, M. Macalpine, Liming Wang, Z. Guan
{"title":"The effect of Applied-voltage on photon-number of corona discharge on transmission lines defect","authors":"S. Wan, Xuesong Zhao, Xinyang Guo, Chen Lan, X. Bian, Wenjun Yao, M. Macalpine, Liming Wang, Z. Guan","doi":"10.1109/CEIDP.2013.6748269","DOIUrl":null,"url":null,"abstract":"Defects of high-voltage transmission lines are often accompanied with corona discharge; and corona discharge would produce ultraviolet. Based on this principle, the UV imager can be used in detecting the defect. Electric field strength is the main factor affecting the corona discharge, which is determined by power-supply and experimental model. In this paper, UV measurement of different defects was studied, and the effect of Applied-voltage on corona discharge of defects was acquired. A quadratic relationship exists between the UV strength produced by corona discharge and applied voltage. The quadratic coefficient A is between 0.31~0.37, which is increase with the length increasing at the experimental conditions in this paper.","PeriodicalId":393969,"journal":{"name":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2013.6748269","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Defects of high-voltage transmission lines are often accompanied with corona discharge; and corona discharge would produce ultraviolet. Based on this principle, the UV imager can be used in detecting the defect. Electric field strength is the main factor affecting the corona discharge, which is determined by power-supply and experimental model. In this paper, UV measurement of different defects was studied, and the effect of Applied-voltage on corona discharge of defects was acquired. A quadratic relationship exists between the UV strength produced by corona discharge and applied voltage. The quadratic coefficient A is between 0.31~0.37, which is increase with the length increasing at the experimental conditions in this paper.
外加电压对输电线路缺陷电晕放电光子数的影响
高压输电线路的缺陷常伴随电晕放电;电晕放电会产生紫外线。基于这一原理,紫外成像仪可用于检测缺陷。电场强度是影响电晕放电的主要因素,它由电源和实验模型决定。本文研究了不同缺陷的紫外测量,得到了外加电压对缺陷电晕放电的影响。电晕放电产生的紫外线强度与外加电压呈二次关系。在实验条件下,二次系数A在0.31~0.37之间,随长度的增加而增大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信