{"title":"2D array microelectrodes for sensing the action potential of the sinoatrial node","authors":"Kevin Ordaz Santamaria, Joel Molina Reyes","doi":"10.1109/LAEDC51812.2021.9437947","DOIUrl":null,"url":null,"abstract":"This paper will introduce some of the most critical parameters, properties, and characteristics of a cell/electrolyte/electrode interface which, along with cell ion channels, electrode/cell coupling, and the instrumentation required for integrated MEA (microelectrode arrays), could enable sensing multiple signals for the detection of action potentials in time and space. A simple and generic fabrication process for MEA development is also introduced along with several conditions that must be met in order to maximize the electrical coupling for higher signal detection. This is applied for sensing multiple action potentials that originated at the sinus node of the heart.","PeriodicalId":112590,"journal":{"name":"2021 IEEE Latin America Electron Devices Conference (LAEDC)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Latin America Electron Devices Conference (LAEDC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/LAEDC51812.2021.9437947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper will introduce some of the most critical parameters, properties, and characteristics of a cell/electrolyte/electrode interface which, along with cell ion channels, electrode/cell coupling, and the instrumentation required for integrated MEA (microelectrode arrays), could enable sensing multiple signals for the detection of action potentials in time and space. A simple and generic fabrication process for MEA development is also introduced along with several conditions that must be met in order to maximize the electrical coupling for higher signal detection. This is applied for sensing multiple action potentials that originated at the sinus node of the heart.
用于检测窦房结动作电位的二维阵列微电极
本文将介绍电池/电解质/电极界面的一些最关键的参数、特性和特征,以及细胞离子通道、电极/细胞耦合和集成MEA(微电极阵列)所需的仪器,可以感知多个信号,以检测时间和空间上的动作电位。还介绍了MEA开发的一个简单而通用的制造过程,以及必须满足的几个条件,以便最大化电耦合以实现更高的信号检测。这是用于感应起源于心脏窦结的多个动作电位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信