Puji Kurniawati, T. E. Purbaningtias, Bayu Wiyantoko, Ganissintya Dewi
{"title":"Analytical method validation for cobalt determination on organic fertilizer","authors":"Puji Kurniawati, T. E. Purbaningtias, Bayu Wiyantoko, Ganissintya Dewi","doi":"10.1063/5.0063062","DOIUrl":null,"url":null,"abstract":"Cobalt determination has been carried out as one of the micro elements in organic fertilizer. The analytical method for the determination of cobalt used SNI 19-7030-2004 about compost from organic domestic waste that has been modified. Sample preparation was carried out by the wet ashing method using 65% nitric acid and perchloric acid. The wet ashing was using the Kjedhal tube for 12 hours. Cobalt determination was carried out using the AAS instrument at λ = 240.7 nm. Validation parameters used were linearity, Limit of Detection (LOD), Limit of Quantitation (LOQ), precision and accuracy. Cobalt content in solid organic fertilizer was 10.32±4.06 mg/kg. Linearity used cobalt standard solution of 0 – 5 mg/L and it produced regression equation with R2 = 0.9971. The Limit of Detection (LOD) and the Limit of Quantitation (LOQ) in this study were 0.015 and 0.029 mg/L. The precision was calculated by the repeatability method with the result of% RSD = 1.21% (≤2%). Accuracy used recovery of spiked matrix. The average% recovery result from 6 repetitions is 90.7% (85-115%). All the validation parameters of the method are in the acceptability range so that this modification method can be used as a routine method in determining cobalt levels in solid organic fertilizer.","PeriodicalId":250907,"journal":{"name":"3RD INTERNATIONAL CONFERENCE ON CHEMISTRY, CHEMICAL PROCESS AND ENGINEERING (IC3PE)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"3RD INTERNATIONAL CONFERENCE ON CHEMISTRY, CHEMICAL PROCESS AND ENGINEERING (IC3PE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/5.0063062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Cobalt determination has been carried out as one of the micro elements in organic fertilizer. The analytical method for the determination of cobalt used SNI 19-7030-2004 about compost from organic domestic waste that has been modified. Sample preparation was carried out by the wet ashing method using 65% nitric acid and perchloric acid. The wet ashing was using the Kjedhal tube for 12 hours. Cobalt determination was carried out using the AAS instrument at λ = 240.7 nm. Validation parameters used were linearity, Limit of Detection (LOD), Limit of Quantitation (LOQ), precision and accuracy. Cobalt content in solid organic fertilizer was 10.32±4.06 mg/kg. Linearity used cobalt standard solution of 0 – 5 mg/L and it produced regression equation with R2 = 0.9971. The Limit of Detection (LOD) and the Limit of Quantitation (LOQ) in this study were 0.015 and 0.029 mg/L. The precision was calculated by the repeatability method with the result of% RSD = 1.21% (≤2%). Accuracy used recovery of spiked matrix. The average% recovery result from 6 repetitions is 90.7% (85-115%). All the validation parameters of the method are in the acceptability range so that this modification method can be used as a routine method in determining cobalt levels in solid organic fertilizer.