High frequency ultrasonic scanning system

J. Hatfield, A. Armitage
{"title":"High frequency ultrasonic scanning system","authors":"J. Hatfield, A. Armitage","doi":"10.1109/MWSCAS.1995.510304","DOIUrl":null,"url":null,"abstract":"Progress towards a high resolution, high frequency, hand-held, ultrasonic scanner is reported. For acceptable image reconstruction, signal quantisation frequency must be of the order of eight times the ultrasonic centre frequency. For ultrasound with centre frequencies in excess of 20 MHz the design problems for hand held devices are formidable. To meet the demanding sampling rate criteria, an undersampling approach is presented. The associated hardware is described and preliminary results are also presented.","PeriodicalId":165081,"journal":{"name":"38th Midwest Symposium on Circuits and Systems. Proceedings","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"38th Midwest Symposium on Circuits and Systems. Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSCAS.1995.510304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Progress towards a high resolution, high frequency, hand-held, ultrasonic scanner is reported. For acceptable image reconstruction, signal quantisation frequency must be of the order of eight times the ultrasonic centre frequency. For ultrasound with centre frequencies in excess of 20 MHz the design problems for hand held devices are formidable. To meet the demanding sampling rate criteria, an undersampling approach is presented. The associated hardware is described and preliminary results are also presented.
高频超声扫描系统
报道了高分辨率、高频率、手持式超声波扫描仪的进展。为了获得可接受的图像重建,信号量化频率必须是超声中心频率的8倍。对于中心频率超过20mhz的超声波,手持设备的设计问题是可怕的。为了满足苛刻的采样率标准,提出了欠采样方法。对相关硬件进行了描述,并给出了初步结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信