Compensation method for the coupling error between the EUT and TEM cell in E-field probe isotropic calibration

Wang Huan, Zhong Chen
{"title":"Compensation method for the coupling error between the EUT and TEM cell in E-field probe isotropic calibration","authors":"Wang Huan, Zhong Chen","doi":"10.1109/ISEMC.2015.7256339","DOIUrl":null,"url":null,"abstract":"TEM cell is widely used as a standard field generating device in the calibration of electric field probes. It is recommended that the EUT shall not exceed one-third of the distance between the floor and the septum in the TEM cell. It will be shown that for measuring isotropic responses of E-field probe (by rotating the probe under a constant incident field), even if the probe meets the one third requirement, the couplings between the probe and the TEM cell are non-negligible. As a result, the total E field inside the TEM cell varies during the rotation of the probe. In this paper, a novel compensation method is presented to remove the coupling effect. The method is based on recognizing the fact that the position of the E-field probe with respect to the TEM cell is periodic through the rotation of the probe. Electric field can be correlated to the rotational angle. Both theoretical analyses and experiment verifications are provided.","PeriodicalId":412708,"journal":{"name":"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)","volume":"98 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2015.7256339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

TEM cell is widely used as a standard field generating device in the calibration of electric field probes. It is recommended that the EUT shall not exceed one-third of the distance between the floor and the septum in the TEM cell. It will be shown that for measuring isotropic responses of E-field probe (by rotating the probe under a constant incident field), even if the probe meets the one third requirement, the couplings between the probe and the TEM cell are non-negligible. As a result, the total E field inside the TEM cell varies during the rotation of the probe. In this paper, a novel compensation method is presented to remove the coupling effect. The method is based on recognizing the fact that the position of the E-field probe with respect to the TEM cell is periodic through the rotation of the probe. Electric field can be correlated to the rotational angle. Both theoretical analyses and experiment verifications are provided.
电磁场探针各向同性标定中EUT与TEM单元耦合误差的补偿方法
瞬变电磁炉作为一种标准场产生装置,广泛应用于电场探针的标定中。建议EUT不应超过TEM单元中地板与隔膜之间距离的三分之一。结果表明,对于测量电磁场探头的各向同性响应(通过在恒定入射场下旋转探头),即使探头满足三分之一的要求,探头与TEM单元之间的耦合也是不可忽略的。因此,在探针的旋转过程中,TEM单元内的总电场是变化的。本文提出了一种新的补偿方法来消除耦合效应。该方法基于认识到电场探头相对于TEM单元的位置通过探头的旋转是周期性的这一事实。电场可以与旋转角度相关联。并进行了理论分析和实验验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信