Effects of SSSC on Distance Relay Tripping Characteristic

A. Kazemi, S. Jamali, H. Shateri
{"title":"Effects of SSSC on Distance Relay Tripping Characteristic","authors":"A. Kazemi, S. Jamali, H. Shateri","doi":"10.1109/PECON.2006.346726","DOIUrl":null,"url":null,"abstract":"This paper presents the measured impedance at the relaying point in the presence of one of the series connected flexible alternating current transmission system (FACTS) devices, i.e. static synchronous series compensator (SSSC). The presence of SSSC on a transmission line greatly influences the tripping characteristic of distance relays. Distance relay tripping characteristic itself depends on the power system structural conditions (short circuit levels at the line ends), pre-fault conditions (load angle and voltage magnitude ratio of the line ends), and especially the ground fault resistance. In the presence of SSSC, its controlling parameters as well as its connection point also affect the tripping characteristic. Here, the measured impedance at the relaying point is calculated due to the mentioned affecting parameters","PeriodicalId":296467,"journal":{"name":"2006 IEEE International Symposium on Industrial Electronics","volume":"91 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Symposium on Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2006.346726","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

This paper presents the measured impedance at the relaying point in the presence of one of the series connected flexible alternating current transmission system (FACTS) devices, i.e. static synchronous series compensator (SSSC). The presence of SSSC on a transmission line greatly influences the tripping characteristic of distance relays. Distance relay tripping characteristic itself depends on the power system structural conditions (short circuit levels at the line ends), pre-fault conditions (load angle and voltage magnitude ratio of the line ends), and especially the ground fault resistance. In the presence of SSSC, its controlling parameters as well as its connection point also affect the tripping characteristic. Here, the measured impedance at the relaying point is calculated due to the mentioned affecting parameters
SSSC对距离继电器脱扣特性的影响
本文介绍了在并联柔性交流输电系统(FACTS)器件,即静态同步串联补偿器(SSSC)存在的情况下,继电点处测量的阻抗。传输线上SSSC的存在极大地影响了距离继电器的脱扣特性。距离继电器跳闸特性本身取决于电力系统的结构条件(线路两端的短路程度)、故障前条件(线路两端的负载角度和电压幅值比),尤其是接地故障电阻。在SSSC存在的情况下,其控制参数和连接点也会影响跳闸特性。在这里,由于上述影响参数,继电点的测量阻抗是计算出来的
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信