Client-server application for the operator panel Weintek and the control system Siemens Simotion

J. Antoš, M. Bušek
{"title":"Client-server application for the operator panel Weintek and the control system Siemens Simotion","authors":"J. Antoš, M. Bušek","doi":"10.1109/CARPATHIANCC.2014.6843559","DOIUrl":null,"url":null,"abstract":"This article describes the communication between the Weintek touch panel and the Siemens Simotion programmable logic controller. This communication is based on the Client-Server architecture. These particular devices from these particular producers ordinarily are not supposed to communicate between each other. With a designed application this communication is possible. Because of this, it is possible to use a robust Simotion control system together with the affordable Weintek HMI. The theoretical part explains how the Client-Server architecture works. The experimental part includes a working application with the above-mentioned communication between the operator panel and the stand for the dynamic test of electronic cams. This method can be applied subsequently in other diagnostic and control applications.","PeriodicalId":105920,"journal":{"name":"Proceedings of the 2014 15th International Carpathian Control Conference (ICCC)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2014 15th International Carpathian Control Conference (ICCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CARPATHIANCC.2014.6843559","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This article describes the communication between the Weintek touch panel and the Siemens Simotion programmable logic controller. This communication is based on the Client-Server architecture. These particular devices from these particular producers ordinarily are not supposed to communicate between each other. With a designed application this communication is possible. Because of this, it is possible to use a robust Simotion control system together with the affordable Weintek HMI. The theoretical part explains how the Client-Server architecture works. The experimental part includes a working application with the above-mentioned communication between the operator panel and the stand for the dynamic test of electronic cams. This method can be applied subsequently in other diagnostic and control applications.
客户端-服务器应用为操作员面板Weintek和控制系统西门子Simotion
本文介绍了Weintek触摸屏与西门子Simotion可编程控制器之间的通信。这种通信基于客户机-服务器体系结构。来自这些特定生产商的这些特定设备通常不应该相互通信。对于设计好的应用程序,这种通信是可能的。正因为如此,它可以使用一个强大的Simotion控制系统与经济实惠的Weintek HMI一起。理论部分解释了客户机-服务器架构是如何工作的。实验部分包括一个利用上述操作面板与台架通信进行电子凸轮动态测试的工作应用。该方法可应用于其它诊断和控制领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信