{"title":"The study of lightning-protection grounding for power dispatching and communication equipment","authors":"L. Dichen, Deng Suqiao","doi":"10.1109/CEEM.2000.853964","DOIUrl":null,"url":null,"abstract":"Because of irrational grounding, the normal work of dispatching and communication equipment is affected heavily, equipment can even be destroyed. The grounding problem for power dispatching and communication equipment in microwave buildings is analyzed in the paper. A comparison between separated and common grounding in different cases is made. An optimal grounding scheme is proposed according to the actual situation. This is of practical significance and theoretical study value for lightning-protection and anti-interference for specially sensitive automation equipment to the outside interference.","PeriodicalId":153945,"journal":{"name":"Proceedings. Asia-Pacific Conference on Environmental Electromagnetics. CEEM'2000 (IEEE Cat. No.00EX402)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. Asia-Pacific Conference on Environmental Electromagnetics. CEEM'2000 (IEEE Cat. No.00EX402)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEEM.2000.853964","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Because of irrational grounding, the normal work of dispatching and communication equipment is affected heavily, equipment can even be destroyed. The grounding problem for power dispatching and communication equipment in microwave buildings is analyzed in the paper. A comparison between separated and common grounding in different cases is made. An optimal grounding scheme is proposed according to the actual situation. This is of practical significance and theoretical study value for lightning-protection and anti-interference for specially sensitive automation equipment to the outside interference.
电力调度和通信设备防雷接地的研究
由于不合理接地,严重影响调度和通信设备的正常工作,甚至可能造成设备损坏。分析了微波建筑中电力调度和通信设备的接地问题。对不同情况下的分离接地和共接地进行了比较。根据实际情况,提出了最佳接地方案。这对于对外界干扰特别敏感的自动化设备的防雷抗干扰具有实际意义和理论研究价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信