{"title":"Comparison of two realisations of a power standard","authors":"I. Budovsky, G. Gubler","doi":"10.1109/CPEM.2016.7540542","DOIUrl":null,"url":null,"abstract":"The paper describes a comparison conducted at the National Measurement Institute Australia (NMIA) between the thermal power comparator that sets the Australian standard of power and the digital power comparator developed at the D. I Mendeleyev Institute for Metrology, Russia. The difference between the two systems did not exceed 5 μW/VA at 53 Hz, 240 V currents of 2.5 A and 4.5 A, and power factors from 0 to 1.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2016.7540542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The paper describes a comparison conducted at the National Measurement Institute Australia (NMIA) between the thermal power comparator that sets the Australian standard of power and the digital power comparator developed at the D. I Mendeleyev Institute for Metrology, Russia. The difference between the two systems did not exceed 5 μW/VA at 53 Hz, 240 V currents of 2.5 A and 4.5 A, and power factors from 0 to 1.