{"title":"Flashovers of Aged Oil-paper Insulation during DC Voltage Preloading","authors":"F. Jin, J. Shi, X. Y. Zhou","doi":"10.1109/ICHVE53725.2022.9961449","DOIUrl":null,"url":null,"abstract":"The study of the flashover characteristics of the aged oil-paper insulation under the AC-DC combined voltage demonstrates that the flashover phenomenon of the aged oil-paper samples along the surface of the insulating paper occurs during the preloading of the higher amplitude DC voltage. Flashover occurs when severely aged oil-paper insulation samples are preloaded with high-amplitude DC voltages. However, flashover is not observed with unaged or “non-severely-aged” samples preloaded with the same DC-voltage amplitude. Therefore, in this study, we examine the space charge, physical, and chemical characteristics of aged oil-paper insulation, in combination with its electric-field distribution characteristics, in the context of the electron-triggered polarization relaxation theory.","PeriodicalId":125983,"journal":{"name":"2022 IEEE International Conference on High Voltage Engineering and Applications (ICHVE)","volume":"266 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on High Voltage Engineering and Applications (ICHVE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE53725.2022.9961449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The study of the flashover characteristics of the aged oil-paper insulation under the AC-DC combined voltage demonstrates that the flashover phenomenon of the aged oil-paper samples along the surface of the insulating paper occurs during the preloading of the higher amplitude DC voltage. Flashover occurs when severely aged oil-paper insulation samples are preloaded with high-amplitude DC voltages. However, flashover is not observed with unaged or “non-severely-aged” samples preloaded with the same DC-voltage amplitude. Therefore, in this study, we examine the space charge, physical, and chemical characteristics of aged oil-paper insulation, in combination with its electric-field distribution characteristics, in the context of the electron-triggered polarization relaxation theory.