Sine-Wave Oscillator for Reflexotherapy Device

A. I. Krokhina, A. Yakovlev
{"title":"Sine-Wave Oscillator for Reflexotherapy Device","authors":"A. I. Krokhina, A. Yakovlev","doi":"10.1109/APEIE.2006.4292444","DOIUrl":null,"url":null,"abstract":"Results of numerical modeling of the binary difractional optical elements (DOE, lenses) operation within the framework of strict electromagnetic theory are presented. Operability of the binary lenses is investigated for the cases when the aperture radius is about ten times of the wavelength and the focal distance varies from the half to two times of the wavelength For the first time the possibility to obtain the resolution of less than the half of the wavelength is demonstrated. The operability of DOE is also revealed for the wavelengths that are different from the designed.","PeriodicalId":425905,"journal":{"name":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 8th International Conference on Actual Problems of Electronic Instrument Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEIE.2006.4292444","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Results of numerical modeling of the binary difractional optical elements (DOE, lenses) operation within the framework of strict electromagnetic theory are presented. Operability of the binary lenses is investigated for the cases when the aperture radius is about ten times of the wavelength and the focal distance varies from the half to two times of the wavelength For the first time the possibility to obtain the resolution of less than the half of the wavelength is demonstrated. The operability of DOE is also revealed for the wavelengths that are different from the designed.
反射疗法装置用正弦波振荡器
给出了在严格电磁理论框架下二元衍射光学元件(DOE,透镜)工作的数值模拟结果。研究了二元透镜在孔径半径约为10倍波长,焦距在1 / 2 ~ 2 / 2波长范围内的可操作性,首次证明了获得小于1 / 2波长分辨率的可能性。对于不同设计波长,DOE的可操作性也得到了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信